Owner's manual
ISM SC Output Board Installation Notes, cont’d
ISM SC configuration menu
Using the front panel menu buttons (Menu and Next), the ISM SC board configuration menu 
can be accessed. From the Output Configuration screen, press Next until reaching the #x 
ScanConverter menu (see the image below). Press Menu and Next to navigate through the 
menus and use the front panel adjustment knobs ({ [), to change the settings as desired.
For full menu details see the ISM 824 User’s Manual, online at www.extron.com.
From the default cycle press Menu repeatedly to reach the Output Configuration 
menu. Press Next (enters Select Output menu) and rotate either adjust knob to 
select the Scan Converter menu. Follow the figure below to enter each menu and 
use the Adjust knobs to change value as desired.
Select Output
#x  ScanConverter
Next
Input Setup
#x  ScanConverter
Aspect Ratio
4:3
Next
Rotate either encoder
to select (4:3 or 16:9)
Next
H  Start    V
xxx       xxx
Rotate encoder to adjust H 
start and to adjust V start
Next
Total Pix  Phase
xxxx     xxxx
Rotate to adjust Total Pix 
value and encoder to adjust 
Phase value
Next
H  Active   V
xxxx     xxxx
Rotate to adjust H active 
value and encoder to adjust
V active value
Menu
Next
Output Config
Next
Next
Rotate either encoder
to select standard
Next
Menu
User Presets
#x  ScanConverter
<NA>  1  2 3
Save Preset
Next
Rotate either encoder
to select a preset to 
save current settings 
<NA>  1  2 3
Erase Preset
Next
Rotate either encoder
to select a preset
to erase 
Advanced Config
#x  ScanConverter
Next
Menu
Next
Next
Rotate encoder to select 
input and encoder to turn 
On or Off
Input #x Off
Auto Image
Next
None
Test Pattern
Rotate either encoder
to select a test pattern
Off   <On>
Next
Auto Memories
Rotate either encoder
to turn auto memories 
On or Off
#x  ScanConverter
YUV
Output Type
Rotate either encoder
to select format
NTSC
Output Standard
Next
x
Flicker Filter
Rotate either encoder
to set a value
Next
x
Encoder Filter
Rotate either encoder
to set a value
Menu
Input #x  <Off>
Next
Full Screen
Rotate to select input # and 
 to turn full screen on or off
Output Standard
The Output Standard submenu displays and allows changes to the output standard. Use the 
Adjust knobs to select between NTSC, NTSC 0 IRE, and PAL.
Flicker Filter
The Flicker Filter reduces the flicker in the connected output display. When this submenu is 
active, rotate either Adjust knob to set the flicker filter value (0-3).
Encoder Filter
The Encoder Filter maintains the sharpness of the connected output display. When this 
submenu is active, rotate either Adjust knob to set the encoder filter value (0-3).
MENU NEXT
ADJUST
2
Input Setup
The Input Setup submenu allows configuration of aspect ratios. 
horizontal and vertical start points, total pixels and phase value, 
and the active horizontal and vertical area. Rotate one or both 
Adjust knobs as required to change values.
Output Type
The Output Type submenu displays and allows changing the 
format of the scan converted output. Use the Adjust knobs to 
select RGsB, low resolution component video (YUV), or S-video.