User Manual
Command ASCII (Telnet) URL Encoded (Web) Response
Bidirectional serial data port
Send data string
E X!
*
X1&
*
X2)
*
X2!
RS
}X@
• W
X!
%2A
X1&
%2A
X2)
%2A
X2!
RS|
X@
response from command
]
Configure parameters
24
E X!
*
X2%
,
X2^
,
X2&
,
X2*
CP
}
W
X!
%2A
X2%
%2C
X2^
%2C
X2&
%2C
X2*
CP
|
Cpn
X!
•Ccp
X2%
,
X2^
,
X2&
,
X2*]
View parameters
E X!
CP
}
W
X!
CP
| X2%
,
X2^
,
X2&
,
X2*]
Configure mode
24
E X!
*
X2(
CY
}
W
X!
%2A
X2(
CY
|
Cpn
X!
•Cty
X2)]
Configure flow control
24
E X!
*
X3)
,
X3!
CF
}
W
X!
%2A
X3)
%2C
X3!
CF
|
Cpn
X!
•Cfl
X3)
,
X3!
View flow control
E X!
CF
} E X!
CF
| X3)
,
X3!]
Configure receive timeout
24
E X!
*
X1&
*
X2)
*
X2#
CE
}
W
X!
%2A
X1&
%2A
X2)
%2A
X2#
CE
|
Cpn
X!
•Cce
X1&
,
X2)
,
X2#]
View receive timeout
E X!
CE
}
W
X!
CE
| X1&
,
X2)
,
X2#]
Configure redirect mode
24
E X!
*
X5)
*
X5#
CD
}
W
X!
%2A
X5)
%2A
X5#
CD
|
Cpn
X!
•Ccd
X5)
,
X5#]
View redirect mode
E X!
CD
}
W
X!
CD
| X5)
,
X5#]
Terminate redirect mode
24
E X!
*0CD
}
W
X!
%2A
0CD
|
Cpn
X!
•Ccd0,0
Flex I/O data port
Set I/O mode (modes 0-5)
X!
*
X4)
[
X!
%2A
X4)
%5B Cpn
X!
•Iom
X4)]
Set I/O mode
(modes 6-7)
X!
*
X4)
*
X5%
*
X5^
[
X!
%2A
X4)
%2A
X5%
%2A
X5^
%5B Cpn
X!
•Iom
X4)
,
X5%
,
X5^
]
View I/O mode
X!
[
X!
%5B
X4)
,
X5%
,
X5^]
NOTE:
X!
= Specific port number (01-99)
X@
= Command data section
X1&
= Time to wait for characters coming into serial port before terminating (default = 10 = 100 milliseconds, max = 32767)
X2)
= Time to wait between characters coming into serial port before terminating (default = 2 = 20 milliseconds, max = 32767)
X2!
= Parameter to set either Length of message to receive or Delimiter value.
X2#
= Priority status for receive timeoutt: 0 = priority set to Send Data String command parameters, 1 = priority set to configure received timeout command
parameters
X2%
= Baud rate: 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600, 14400, 19200, 28800, 38400, 57600, 115200
X2^
= Parity: Odd, Even, None, Mark, Space (only first letter is required)
X2&
= Data bits: 7, 8
X2*
= Stop bits: 1, 2
X2(
= Port type: RS-232, RS-422, RS-485 (or 0,1, or 2, respectively). (
X2(
= 0 for the SFI244)
X3)
= Flow Control: Hardware, Software, None (only first letter is required)
X3!
= Data pacing: 0000-1000 (default = 0 milliseconds)
X4)
= I/O mode:
0 = input; 1 = output; 2 = input plus pull-up resistor; 3 = output plus pull-up resistor; 4 = analog in; 5 = analog in w/pull-up; 6 = adjust in
(requires
X5%
&
X5^
thresholds); 7 = adjust in w/pull-up (requires
X5%
&
X5^
thresholds).
X5%
&
X5^
thresholds are not required for modes 0-5.
X5)
= Redirect: 0 = no redirect; 1-n= redirect serial port from the specified port to allow for a transparent pass-through mode
X5#
= Timeout for data pass-through mode, after which event data can be inserted into the transparent buffer
X5%
= Upper transition threshold (0 detection = off) for digital inputs
X5^
= Lower transition threshold (1 detection = on) for digital inputs
Command/response table for SIS commands
IPL T SFI244 • Communication and Control 36