User`s manual
IPL T SF Series • Communication and Control
Communication and Control, cont’d
4-20
X4^
= E-mail recipient address: maximum number of characters for a full e-mail
address is 31 characters.
X4&
= Name of e-mail file to be sent: the first line of the file is the subject, the rest is
the body of the e-mail.
N
E-mail files must have the file extension .eml.
X4*
= Event Status fields (8): event_type, event_state, event_paused, error_status,
RcvBuff_endptr, UsrBuff_startptr, UsrBuff_endptr
X4(
= Default Name: Combination of model name and last 3 pairs of MAC address
(e.g., IPL-T-SFI244-00-02-3D)
X5)
= Redirect: 0 = no redirect; 1-n = redirect serial port from the specified port to
allow for a transparent pass-through mode
X5@
= Connection’s security level: 0 = not logged in; 1 = user; 2 = administrator
X5#
= Timeout for data pass-through mode, after which event data can be inserted
into the transmit buffer.
X5$
= ASCII digit(s) representing numeric value of data element read from event
buffer (leading zeros are suppressed)
X5%
= Upper transition threshold (0 detection = off) for digital inputs; Lower must
be smaller than upper (0-4095 based on 12-bit A to D)
X5^
= Lower transition threshold (1 detection = on) for digital inputs; Lower must
be smaller than upper (0-4095 based on 12-bit A to D)
N
The default Web pages display
X5%
and
X5^
in voltages. (100 mV to
24 VDC, upper default = 2 VDC and lower default = 1 VDC). The
conversion rate is 162 counts to 1V.
X5&
= IR playback file
X5*
= IR function number
X5(
= IR playback mode: 0 = play once, 1 = play continuously (send IR command
again with mode = 0 to stop mode 1 playback)
X6)
= IR Learn starting sample # to return (0 = return all data)
X6!
= IR Learn ending sample # to return (0 = return all data)
X6@
= IR Learn status: 0 = finished, but no IR seen; 1 = finished, buffer overrun;
2 = finished, successful collection; 3 = finished, but aborted; 4 = waiting for
first pulse; 5 = busy collecting
X6#
= Pulse time in 20 ms per count. If parameter is missing or = 0,
pulse length = default (25 counts=500 ms), max (65536 counts)
X6$
= Broadcast repetition rate in seconds (0-256. 0 = disable)
Copyright information
]
© COPYRIGHT 2003, EXTRON ELECTRONICS IPL T Mxx,
Vx.xx
]
Thurs, 20 Feb 2003 17:51:04
]
The copyright message is displayed upon connecting to IP Link
product via TCP/IP or Telnet. Mxx is the model and Vx.xx is
the firmware version number. The current date and time are
displayed. This is followed by a password prompt.