User`s manual

IPL T SF Series • Communication and Control
Communication and Control, cont’d
4-4
Figure 4-4 — High and low transitions of
adjustable threshold with deadband (hysteresis)
Digital output
When a ex I/O port is congured as a digital output, it is set
to offer two output states: “on” and “off”. When the port is
set to an “on” state, (SW1 is closed), the I/O pin is connected
to ground (each I/O port is capable of sinking 250 mA max.).
When the port is set to the “off” state, (SW1 is open), the output
pin is oating.
If the application calls for TTL compatibility, SW2 can be
selected to provide a 2K pull-up resistor to +5 VDC.
Figure 4-5 — Sample of a digital output port
driving an LED using an external +5 VDC source