User`s manual

IPL T CR48 • Specications, Part umbers, and Accessories
Specifications, Part Numbers, Accessories
A-2
Specifications
Ethernet control interface
Connectors ..................................... 1 RJ-45 female connector
Data rate ......................................... 10/100Base-T, half/full duplex with
autodetect
Protocols
......................................... ARP, DHCP, ICMP (ping), TCP/IP, UDP/
IP, Telnet, HTTP, SMTP
Default settings
.............................. Link speed and duplex level =
autodetected
IP address = 192.168.254.254
Subnet mask = 255.255.0.0
Gateway = 0.0.0.0
DHCP = off
Web server
...................................... Up to 200 simultaneous sessions
1.25 MB nonvolatile user memory
Program control
............................. Extron’s Simple Instruction Set (SIS
)
Global Viewer requirements
........ Microsoft
®
Internet Explorer ver. 6 or
higher
Relay control interface
Quantity/type ............................... 8 normally open relays
Relay control connectors .............. (2) 3.5 mm captive screw connectors, 8
pole
Relay control contact rating
......... 24 V, 1 A
Contact closure control interface
Quantity/type ............................... 4 contact closure inputs
Contact input control connector . (1) 3.5 mm captive screw connector, 5 pole
Contact closure (input only)
Input voltage range
........... 0 to 5 VDC, clamped at +5.1 V
Input impedance ............... 10k ohms
Threshold............................ 1.6 VDC
Pin congurations ......................... 1, 2, 3, 4 = inputs 1, 2, 3, 4; 5 = GND
General
Power .............................................. Supplied by an included external power
supply
External power supply
................. 100 VAC to 240 VAC, 50/60 Hz, external;
to 12 VDC, 1 A, regulated
Power input requirements
........... 12 VDC, 0.5 A