User`s manual
IPL T CR48 • Communication and Control
Communication and Control, cont’d
4-16
Command ASCII (Telnet) URL Encoded (Web) Response
Query factory rmware
version
3Q 3Q
X1!
(plus web ver.-desc-UL
date/time)
]
Query updated rmware
version
4Q 4Q
X1!
(plus web ver.-desc-UL
date/time)
]
N
An asterisk (*) placed after the version number indicates which version is currently running. A question mark (?) indicates that only the
factory firmware version is loaded. A caret (^) after the version number indicates the firmware version that should be running, but a Mode
1 reset was executed. The default factory firmware version is loaded. An exclamation point (!) after the version number indicates corrupted
firmware.
Request part number N N
60-544-05
]
Request model number 1I 1I IPL T CR48
Request model
description
2I 2I Four contact input ports ,
Eight relay ports
]
Request system memory
usage
3I 3I # bytes used out of #
kbytes
]
Request user memory
usage
4I 4I # bytes used out of #
kbytes
]
IP Setup Commandsz
Set Unit name
E X1@
CN
}
W
X1@
CN| Ipn •
X1@]
Set Unit name to factory
default
24
E
•CN
}
W%20CN|
Ipn •
X4(]
N
X1! = Unit version number
X1@ = Name is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9), and/or a minus sign/hyphen (-).
X4( = Default Name: Combination of model-name and last 3 pairs of MAC address (e.g., IPL-T-CR48-00-02-3D)