Setup guide
3
TLP 700MV • Setup Guide
h
Reset button — recessed behind the faceplate. Four different reset modes are available with TouchLink panels
(see below).
i
Menu button — recessed behind the faceplate. It activates the on screen menus for setting up the panel and
calibrating the unit.
j
Reset LED — recessed behind the faceplate. It is visible only when the faceplate has been removed. It lights as
an indicator for the Reset modes.
Configuring the TLP 700MV (Initial Setup)
Before using the TLP 700MV, it is essential to configure it, using the on-screen menus. There are five different
screens (Main, Volume, Time, Network, and Video) that can be selected by pressing the appropriate button at the
left side of the screen. There is also an Exit button at the bottom left corner of the screen for leaving the menus.
Enter the Setup Menu
1. Press the recessed Menu button to activate the top-level
menu screen. The menu opens at the Main Setup Page.
2.
Touch an area of the screen to bring it into focus and use the
up and down buttons or the volume control knob to adjust
the value. Some options have a single button and toggle
between Off and On when pressed.
Use the different menu pages to adjust the following options.
For more details, see the Reference Manual.
Main (shown at right) — Adjusts the Sleep timer, Backlight,
Auto Backlight, LED Backlight, and Wake on Motion functions.
Volume — Adjusts the Master, Click, Sound, and Line In
volume settings.
Time — Sets up the correct time and date.
Network — Sets the IP address, the subnet mask, and enables
or disables Dynamic Host Configuration Protocol.
Video — provides a small video preview window and the
controls to set up the video contrast, color, brightness, and tint.
Enter Calibration Menu
1. Press the Menu button a second time to open the calibration
screen. Once all four points have been calibrated, the screen
reopens to the Setup Screen.
2.
Press Exit to close the on-screen menus.
3.
Reattach the faceplate.
Reset Modes
The TLP 700 MV has four reset modes that can be initiated by pressing the Reset button:
Factory Firmware Mode: Hold the Reset button while applying power to reset the unit back to the base firmware
shipped with the unit.
Run/Stop Events Mode:
Hold the Reset button until the reset LED blinks once (3 sec.), then release and press Reset
momentarily (<1 sec.) within 1 second. This mode turns events either On or Off.
Reset All IP Settings Mode:
Hold the Reset button until the reset LED blinks twice (6 sec.), then release and press
Reset momentarily (<1 sec) within 1 second. This mode resets the IP address, subnet, gateway, port mapping, and
DHCP settings back to factory defaults. The reset LED blinks 4 times in quick succession, confirming the reset and
turning events off. If necessary, reset the IP address, using ARP and the MAC address.
Reset Factory Defaults Mode: Hold the Reset button until the reset LED blinks 3 times (9 sec.), then release and
press Reset momentarily (<1 sec) within 1 second. This mode causes an complete reset to factory defaults (except
firmware).
N
See the Reference Manual for additional details.
Setup Screen
Calibration Screen