User Guide Owner manual

IPCP Pro Series • Hardware Features and Installation 14
C
Switched 12 VDC power output portsThese ports provide 12VDC output. For
the IPCPPro550, the four ports provide up to a combined maximum of 40watts. Once
configured, each port can be separately turned on or off. These ports are monitored
continuously for total power usage (draw).
21
LIMIT
SWITCHED
12 VDC
OVER
43
12 VDC
SWITCHED 12 VDC
40W MAX TOTAL
3 4
1 2
Lights if total power draw
is 41-44 watts.
Lights if total power draw
exceeds 47 watts.
Power output shuts off
until the user corrects the
overload.
Switched 12 VDC
Power Output
12 VDC, 40 watts (max.)
= total output for all four ports
combined
Corresponding front panel
green LEDs ( ) light when
power is available at each port.
3/16"
(5 mm)
Max.
Rear
Pa
nel
Front
Panel
Tie Wrap
Figure 9. Switched Power Output Ports and LEDs
When the total power usage exceeds a threshold of 41watts but is still below
45watts, the IPCP enters the limit mode, during which the yellow front panel
Limit LED lights. If you have configured the unit to do so, the IPCP can issue a power
overcurrent notice.
If power usage exceeds a second, higher threshold (47watts), the IPCP enters
overcurrent mode. It turns these ports off, and the red front panel OverLED lights.
If the ports are disabled, the user must disconnect or fix the attached devices to
correct the problem. If the power draw is still excessive, the ports remain off.
PRELIMINARY