RS232 Commands
Programming and information polling is also possible by RS232 communication through the RS232
connector on the back of the unit. Connection is made via an IN9317 connector wired to either a 9-pin D
or 25-pin D connector. The input labeled GND (pin2) goes to either pin 7 of a 25 pin connector or pin 5
of a 9 pin. The input labeled TX (pin1) goes to either pin 3 of a 25 pin connector or pin 2 of a 9 pin
connector. The input labeled RX (pin3) goes to either pin 2 of a 25 pin connector or pin 3 of a 9 pin
connector. Default communication settings are 8 bits, 1 stop bit, no parity and 1200 baud. All commands
sent to the unit must be enclosed in brackets. When linking units together, up to four units can be
programmed with different brackets for an ID when communicating with all units. Possible brackets are [
and ], { and}, ( and ), < and >. The default brackets are [ and ]. So a command sent to the unit would look
like: [BLANK0]. Letters are not case sensitive and can be written as BLANK or blank. Possible
commands are:
ACI3 Set to 1200 Baud
ACI4 Set to 2400 Baud
ACI5 Set to 4800 Baud
ACI6 Set to 9600 Baud
BLANK0 Blank Output (Same as Blank key)
BLANK1 Un-Blank Output (Return to previous channel)
BLANKB Set for BLANK=BLANK
BLANKS Set for BLANK=SYNC
CH0 Select Blank (Same as Blank0)
CH1,2,3,4,5,6 Select Channel 1,2,3,4,5,6
CMDCD0,1,2,3Set unit for commands with [ ], { }, ( ) or < > respectively
FP Front Panel Enable/Disable Toggle
FP0 Front Panel Disable
FP1 Front Panel Enable
INF0 Display Model Number and Software Version
INF1 Display Current Channel
INF2 Display all setup parameters
Mode0 Manual Mode
Mode1 Autoswitching
Mode2 Turn on Vertical Switching
Mode3 Turn off Vertical Switching
Mode4 Set as Master
Mode5 Set as Slave
RGBx x=RGB Delay Time (i.e. [RGB2.5] )
Possible allowable times are: 0.5 seconds 1.0 seconds 1.5 seconds
2.0 seconds 2.5 seconds 3.0 seconds
3.5 seconds 4.0 seconds 4.5 seconds
5.0 seconds 5.5 seconds 6.0 seconds
6.5 seconds 7.0 seconds 7.5 seconds
Scan0 Disable Scanning
Scan1 Enable Scanning
Scan2,3,4,5,6 Scan to Channels 2,3,4,5,6