Operation Manual 2-Input, 1-Output Switcher Series: IN3552R - RGBHV Switcher IN3562R - VGA Switcher
Installation and Safety Instructions For Models without a Power Switch: The socket outlet shall be installed near the equipment and shall be accessible. For all Models: No serviceable parts inside the unit. Refer service to a qualified technician. For Models with Internal or External Fuses: For continued protection against fire hazard, replace only with same type and rating of fuse.
1 DESCRIPTION The IN3552R and IN3562R are high performance analog video switchers featuring two inputs and one output. These switchers are designed to route high resolution source signals to an attached video projector, monitor, LCD panel or color printer. Users may select the desired input channel using the front panel channel select button or via remote control by using a wired remote, third-party control system, or any other device capable of providing a latching contact closure.
2 INSTALLATION This section offers step-by-step instructions for installing IN3552R / IN3562R switchers. A detailed application drawing showing all equipment connections is shown on the next page. 1. Connect both sources to the IN3552R / IN3562R input connectors. IN3552R: An interface may be required for each computer video signal source in order to split off a signal for each local monitor, bring all signals into the RGBHV format, and amplify the signal to compensate for long input/output cable runs.
Application Diagram - IN3562R Local Monitor IN3262 / IN3262D INPUT OUTPUT 2 OUTPUT 1 PC with VGA Out Data Projector / Data Monitor 3262® HIGH RESOLUTION VGA DISTRIBUTION AMPLIFIER IN8000 Series VGA Cables IN3562R INPUT 1 INPUT 2 OUTPUT REMOTE STAT 120/230VAC; 0.
4 OPERATION Input Selection The IN3552R / IN3562R two input switchers provide a front panel button which may be used to select the desired input channel. Each time the SELECT button is pressed the unit toggles back and forth between Input 1 and Input 2 and the appropriate front panel LED indicator lights to show the current channel selection. The non-selected channel is terminated into 75 Ohms. The switcher automatically returns to the last selected channel if power is removed and reapplied to the unit.
5 Contact Closure Devices Any device capable of providing a latching contact closure may be used to control the IN3552R / IN3562R. Several contact closure type control devices are available: IN6901 / IN6902 RS-232 to Contact Closure Converters - allow IN3500 Series switchers and other INLINE devices with contact closure control ports to be controlled by RS-232 sources such as control systems and computer serial ports. Control System - many control systems are capable of providing contact closures.
6 INTERNAL FUSES The IN3552R / IN3562R switchers contain two internal fuses. If power is applied to the unit and neither of the front panel LEDs is illuminated, these fuses may be blown. Open the case as described below, locate the two fuses as indicated in the diagram below and replace blown fuses as required with new 200mA / 250V fuses. J7 C1 Fuse F1 Fuse F2 Caution: The case opening procedure should only be done by a qualified technician in a static-free environment.
7 SPECIFICATIONS IN3552R RGBHV Switcher IN3562R VGA Switcher 5 BNC Female 15 Pin HD Male 2 Inputs 2 Inputs 5 6 RGBHV, RGBS, RGsB, RsGsBs, Monochrome with Sync, Composite Video, Y/C, Component Video, Audio RGBS, RGsB, RsGsBs, RGBHV, RGBHVS Monochrome with Sync, Composite Video, Y/C, Component Video, Audio 5 BNC Female 15 Pin HD Female 650 MHz .7Vp-p input signal @ - 3dB 500 MHz .
8 Parts Included IN3552R AC Power Cable (U.S. Only) Operations Manual IN3562R AC Power Cable (U.S. Only) Operations Manual Optional Accessories Rack Mounting Equipment IN9080 Rack Shelf – Holds Two Units Side-By-Side IN9088 Blank Panel – Fills empty space when using IN9080 Rack Shelf with only one IN3552R or IN3562R switcher. TROUBLESHOOTING The display device connected to the switcher output has a bad/scrambled image.
9 WARRANTY ♦ INLINE warrants the equipment it manufactures to be free from defects in materials and workmanship. ♦ If equipment fails because of such defects and INLINE is notified within three (3) years from the date of shipment, INLINE will, at its option, repair or replace the equipment at its plant, provided that the equipment has not been subjected to mechanical, electrical, or other abuse or modifications.