IN2118 ELEVATING TABLE MOUNTABLE INSTALLATION INTERFACE WITH MODULAR A / V CONNECTOR FACEPLATES IN2118 OPERATION MANUAL
Installation and Safety Instructions For Models without a Power Switch: The socket outlet shall be installed near the equipment and shall be accessible. For all Models: No serviceable parts inside the unit. Refer service to a qualified technician. For Models with Internal or External Fuses: For continued protection against fire hazard, replace only with same type and rating of fuse.
Table of Contents Product Overview ................................................................................................ 2 Description........................................................................................................ 2 Eighteen Models Available............................................................................... 2 Compatibility........................................................................................................ 3 Input ...........................
2 Product Overview DESCRIPTION The IN2118 is a high performance computer video interface for analog video signals including VGA, SVGA, XGA, SXGA, UXGA, Macintosh®, SunTM, SGITM and other high-resolution workstations. The IN2118 flush mounts neatly in a conference room / boardroom table or other presentation furniture.
3 The IN2118 Interface is not a scan converter. The data projector, monitor or other output device must be compatible with the horizontal scan rate, vertical scan rate and resolution output by the computer video card. Compatibility INPUT The IN2118 Interface will accept high-resolution video signals from virtually any computer that outputs an analog video signal. The unit will work with signals at virtually any resolution and refresh rate.
4 Installation MOUNTING THE INTERFACE WARNING: The IN2118 should only be mounted by licensed and bonded installers. Care must be taken to avoid scarring or damaging presentation / conference room furniture. Before installing the IN2118, refer to the Dimensions Diagrams on pages 22 - 24 and make sure the table / installation furniture will accommodate all the dimensions of the unit. In the following example, the IN2118 is installed in a conference room table with a laminated surface.
©2001 - Inline, Inc.
6 5. Most installations will require fabrication of a new cover surface (lid). Using the IN9185 template, make another outline on a matching piece of material. Cut out the new lid using a power / saber saw. Note: Bear in main that the new surface must accommodate a 1/32” gap on all four sides between the lid and the table opening. 6. Finish the top and sides of the lid, and the sides of the opening in the table.
7 ADJUSTING THE IN2118 This section offers step-by-step instructions for precisely situating the IN2118 in the table / presentation furniture. An Adjustment Diagram is provided on the following page. Do not permanently attach the cover surface (lid) to the top plate until the IN2118 has been fully installed in the table / presentation furniture. 1.
A: IN2118 Operation Manual - Preliminary 02/05/01 8 120/230VAC; 60/50HZ ©2001 - Inline, Inc.
9 MAXIMUM BEARING LOAD In applications where the unit will be raised and lowered by hand or through the contact closure control port, the maximum weight of the cover surface material affixed to the top of the interface (the lid) should not exceed 10 pounds / 4.5 kilograms. The maximum load bearing on the motor is 30 pounds, but exceeding the 10 pound / 4.5 kilogram load limit will shorten the life of the motor and may compress the activation spring, preventing the unit from operating properly..
10 5. Connect the Left, Right and Ground Conductors on the audio cables to the 5-pin captive screw terminal. This connector will accept stranded or solid cables from 20 - 26 AWG. The IN2118 Interface takes an unbalanced stereo audio input, buffers the signal and outputs it as balanced stereo audio.
11 12. Connect the Local Computer Monitor (if applicable) to the local monitor output port of the IN2118. Monitors with 15-pin VGA connectors will attach directly to the interface. For other types of monitors, refer to the table below. If a local monitor is required, the monitor emulation dipswitch must be disabled (see the Dipswitch Settings Section on page 15 for more details).
12 IN2118 Operation Manual - Preliminary 01/31/01 ©2001 - Inline, Inc.
©2001 - Inline, Inc.
14 IN2118 Operation Manual - Preliminary 01/31/01 ©2001 - Inline, Inc.
15 Operation HORIZONTAL POSITION CONTROL The location of the horizontal position control is shown in the Faceplate A Connectors and Controls Diagram on the previous page. This control adjusts the position of the image on the data display device. The horizontal position control has no effect on the local computer monitor.
16 OPTIMAL SETTINGS FOR LCD / DLP / D-ILA / PLASMA DISPLAYS The following output sync settings provide maximum signal preservation and are recommended for the best image quality with LCD, DLP, D-ILA and Plasma Display devices. Depending on the design of the display device’s sync processing circuitry, you may be able to set the horizontal position control (dipswitch #1) to the enabled position.
17 A/V CONNECTOR MODULES Connector Module Black / White Video Modules IN9351B / IN9351W IN9352B / IN9352W IN9357B / IN9357W IN9363B / IN9363W IN9381B / IN9381W IN9382B / IN9382W IN9383B / IN9383W IN9390B / IN9390W IN9468B / IN9468W Audio Modules IN9353B / IN9353W IN9354B / IN9354W IN9355B / IN9355W IN9360B / IN9360W IN9365DB / IN9365DW IN9373B / IN9373W IN9384B / IN9384W IN9385B / IN9385W IN9395DB / IN9395DW IN9398DB / IN9398DW IN9450B / IN9450W IN9451B / IN9451W IN9456B / IN9456W IN9457B / IN9457W IN9458B
18 Connector Module Black / White Control / Computer Modules IN9356B / IN9356W IN9360B / IN9360W IN9361B / IN9361W IN9362B / IN9362W IN9364DB / IN9364DW IN9366DB / IN9366DW IN9374B / IN9374W IN9375B / IN9375W IN9378B / IN9378W IN9379B / IN9379W IN9389B / IN9389W IN9391DB / IN9391DW IN9394DB / IN9394DW IN9396DB / IN9396DW IN9397DB / IN9397DW IN9399B / IN9399W IN9452B / IN9452W IN9460B / IN9460W IN9464B / IN9464W IN9465B / IN9465W IN9466B / IN9466W IN9467B / IN9467W IN9470B / IN9470W IN9471B / IN9471W IN94
19 Specifications IN2118 Installation Video Interface Input (IN2118-A, D & G only) Connector Type (1) 15-pin HD female RGB Video Signals Analog, 1.5 Vp-p max. Sync Signals TTL compatible Horizontal Scan Rate 30 KHz - 130 KHz Vertical Sync Range 30 Hz - 120 Hz Stereo Audio Connector (1) 3.
20 Required Accessories (Ordered Separately) Input and Local Monitor Adapter and Extension Cables: VGA: IN8000 Series 15-pin HD female to 15-pin HD female, various lengths from 3’ to 100’ For Other Computers: Refer to the table on page 11 Optional Accessories Table Routing Template IN9185: Provides a guide to make a precision cut when mounting the IN2118 in a table / presentation furniture Remote Equipment: IN6901 / IN6902: RS-232 to contact closure converter IN9465: Rocker Switch Module Audio Input Cable
21 data monitors and data projectors are not compatible with these resolutions and frequencies. Solution 3: Check the dipswitch settings to make sure the unit is putting out a sync format that the display device can use. For most applications, the default dipswitch settings (see page 15) will work best. Solution 4: The RGBS or RGBHV cable may have a bad sync line. Try running the sync through another cable. Problem: The output image is very dark.
22 0.625" IN2118 Operation Manual - Preliminary 01/31/01 ©2001 - Inline, Inc.
23 ©2001 - Inline, Inc.
24 BOTTOM VIEW IN2118 Operation Manual - Preliminary 01/31/01 ©2001 - Inline, Inc.
25 Warranty ♦ INLINE warrants the equipment it manufactures to be free from defects in materials and workmanship. ♦ If equipment fails because of such defects and INLINE is notified within two (2) years from the date of shipment, INLINE will, at its option, repair or replace the equipment at its plant, provided that the equipment has not been subjected to mechanical, electrical or other abuse or modifications.