Manual
36 
© 2002 - INLINE, Inc.    IN1408 Operation Manual - V1.4 3/21/02 12:32 PM 
Remote Operation 
RS-232 CONTROL 
The IN1408 RS-232 serial control port accepts serial commands from a control system, computer 
serial port, or any other device capable of sending out serial ASCII commands at compatible baud 
rates. A complete listing of RS-232 codes is included on the following pages. 
Communication Protocol: 
8 data bits 
1 stop bit 
No parity check 
9600 baud (factory default setting) 
Baud Rate Selection: 
The IN1408 has a factory default baud rate of 9600 bps and can communicate at baud rates from 1200 
up to 57,600. Baud rates can be selected using the Advanced Menu (see page 23). 
Á  Note:
 The baud rate transmitted must match the baud rate selected on the IN1408 
Command Code Structure and Delimiters: 
All commands sent to the unit must contain a leading code, the command code, and an ending code. 
Each command must be completely executed before the unit will accept a new command. 
INLINE scalers can be set to recognize six sets of leading and end codes (delimiters) when using an 
RS-232 remote: parentheses ( ), brackets [ ], braces{ }, slashes \ /, less and greater than < >, and 
signs !#. The factory default serial delimiters are [ ]. 
Note: Only the IN1408 that has the same delimiters as the remote controller will respond. 
A complete command consists of: 
  [  The leading code 
  CH3  The command code. 
  ]  The ending code 
Example: [CH3] commands the IN1408 to select channel 3. 
Serial Control Cable Wiring 
When controlling only one IN1408 unit, connect the RS-232 cable as follows: 
Controller Transmit  to  IN1408 Receive 
Controller Ground  to  IN1408 Ground 
Controller Receive  to  IN1408 Transmit 
When controlling multiple IN1408 units, connect the RS-232 cable as follows: 
Controller Transmit  to  Each IN1408 Receive 
Controller Ground  to  Each IN1408 Ground 
Controller Receive  to  Only one IN1408 Transmit 
Key Concept 
When controlling multiple units, the Controller Receiver Terminal must con-
nect to only one IN1408 Transmit Terminal. Multiple IN1408 Transit Lines 
may not be connected together; otherwise signal contention from multiple 
units will result. Therefore, “receive” information is only available from one 
IN1408 in this configuration. Each unit must be set to different delimiters.