User guide

FOX T UWP 302 Wallplate Transmitter • Installation and Operation 11
4. Connect all cables to the FOX T UWP 302 rear panel connectors.
5. Secure the FOX T UWP 302 enclosure to the box using three of the provided screws
into the slots at the top and bottom of the device (see figure 6,
2
on the previous
page).
6. Fasten the Decora wallplate onto the enclosure using six of the provided screws in the
holes at the top and bottom (see figure 6,
3
).
Connecting the HDMI Connector
Use an Extron LockIt lacing bracket to secure an HDMI cable to each device.
1. Plug the HDMI cables into the panel connection
(see
1
of the image to the right).
2. Loosen the side HDMI connection mounting screw from
the panel enough to allow the LockIt lacing bracket to
be placed over it (
2
). The screw does not have to be
removed.
3. Place the LockIt lacing bracket on the screw and against
the HDMI connector, then tighten the screw to secure
the bracket (
3
).
ATTENTION: Do not overtighten the HDMI
connector mounting screw. The shield to which it is
fastened is very thin and can easily be stripped.
ATTENTION : Ne serrez pas trop la vis de montage
du connecteur HDMI. Le blindage auquel elle
est attachée est très fin et peut facilement être
dénudé.
4. Loosely place the included tie wrap around the HDMI connector and the LockIt lacing
bracket (
4
).
5. While holding the connector securely against the lacing bracket, use pliers or a similar
tool to tighten the tie wrap, then remove any excess length.
Wiring for Remote RS-232 and Alarm Communication
The Remote RS-232 and Alarm connector is for RS-232 control (such as updating firmware,
status queries, and various control functions) and the alarm feature. Wire the connector as
shown in figure 7 below.
RxTx
Alarm Device
RS-232 Device
G
REMOTE
RS-232 ALARM
Tx Rx G12
12
Figure 7. Wiring the Remote RS-232 and Alarm Connector
1
2
3
4