User guide
FOX T USW 203 Universal Switcher • Installation 7
Control Connectors
H
Contact closure connector — Connect a contact closure device (such
as a simple switch) to the 3.5 mm, 4-pole captive screw connector.
The first three ports are used for selecting inputs 1 through 3 when
momentarily shorted to the ground pin (see Wiring for Remote Contact
Closure Communication on page 9).
I
Remote RS-232 connector — Connect a host device to the 3.5 mm,
3-pole captive screw connector for serial control of the switcher.
Power Connector
J
Power connector — Connect an external power supply to the 3.5 mm, 2-pole
captive screw connector (see Wiring the Power Supply on page 9).
Connection Details
Connecting HDMI Connectors
Use an Extron LockIt lacing bracket to secure an HDMI cable to each device.
1. Plug the HDMI cables into the panel connection
(see
1
of the image to the right).
2. Loosen the side HDMI connection mounting screw from
the panel enough to allow the LockIt lacing bracket to
be placed over it (see
2
). The screw does not have to
be removed.
3. Place the LockIt lacing bracket on the screw and
against the HDMI connector, then tighten the screw to
secure the bracket (see
3
).
ATTENTION: Do not overtighten the HDMI
connector mounting screw. The shield to which it is
fastened is very thin and can easily be stripped.
ATTENTION : Ne serrez pas trop la vis de montage
du connecteur HDMI. Le blindage auquel elle
est attachée est très fin et peut facilement être
dénudé.
4. Loosely place the included tie wrap around the HDMI connector and the LockIt lacing
bracket (see
4
).
5. While holding the connector securely against the lacing bracket, use pliers or a similar
tool to tighten the tie wrap, then remove any excess length.
1
2
3
4
CONTACT
12
3G
RS-232
Tx Rx G
POWER
12V
0.8A MA