X1# =  Number of open connections  0 – 200
X1$ =  Password  12 alphanumeric characters
NOTE:  The HTML language reserves certain characters for specific functions (see “Special Characters” on page 28).
X1%  = DHCP  0 =off, 1 = on
X1^ =  Baud rate  9600, 19200, 38400, 115200
X1&  = Parity  odd, even, none, mark, space (Only the first letter required.)
X1* =  Data bits  7, 8
X1( =  Stop bits  1, 2
X2) =  Port type (always 0 = RS-232)
X2! =  Verbose mode  0 = clear/none (default for Telnet connection)  2 = tagged responses for queries 
1 = verbose mode (default for RS-232)  3 = verbose mode and tagged for queries
NOTE:  If tagged responses is enabled, all read commands return the constant string and the value as the set command does 
(for example, the read matrix name command, 
E
CN
}
,returnsIpn•
X%]
).
X2@ =  Port timeout interval (in 10-sec. increments)  1 (= 10 seconds) – 65000 (default is 30 = 300 seconds = 5 minutes)
X2# =  Direct access port map  0 (= disabled) or 1024 and up (default is 2001)