User guide

Command and Response Table for SIS Commands (continued)
Command Function SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Reclocking
NOTES:
Laser board reclockers are set on a per SFP basis. If an SFP is reclocked, the corresponding input and output reclockers reclock
at the same rate.
HD-SDI reclockers are set on a per output basis only.
If the connected input or output device is a FOX USB Extender unit, ensure that the re-clockers are set to bypass mode.
Set output reclocker
X$
*
X%
= Rte
X$
*
X%]
Set the rate for reclocker
X$
to
X%
.
Example:
8*00=
Rte08*00
]
Set the rate for reclocker 8 to auto.
Read reclocker status
X$
=
X%]
Show current rate status for reclocker
X$
.
Laser controls
Enable individual laser driver
EX@
*1FIBR
}
Fibr
X@
*1
]
Enable the laser for output
X@
. The laser lights
so long as power is applied.
Disable individual laser driver
EX@
*0FIBR
}
Fibr
X@
*0
]
Disable the laser for output
X@
. The laser is off.
Set individual output laser
driver to automatic
EX@
*2FIBR
}
Fibr
X@
*2
]
Set the laser driver for output
X@
to automatic.
The laser lights when a tie is made to output
X@
,
but is off when no tie is made to output
X@
or
the output is muted.
Read status of all laser
drivers
E
FIBR
} X^
1
X^
2
X^
3
X^
4
...
X^
n
]
List the laser driver status of all installed outputs.
n is the highest numbered output for your switcher.
Global laser enable
E
1*FIBR
}
Fibr1]
Enable all output laser drivers.
NOTE: If your switcher has any BNC 3G/HD/SD-SDI boards installed, the global commands are not available. The switcher returns E14.
Global laser disable
E
0*FIBR
}
Fibr0]
Disable all output laser drivers.
Global laser automatic
E
2*FIBR
}
Fibr2]
Set all output laser drivers to automatic.
Save, recall, and directly write global presets
NOTES:
If you try to recall a preset that is not saved, the matrix switcher responds with the error code E11.
The following characters are invalid or not recommended in preset names: + - , ` @ = [ ] { } ; : | \ and ?.
Save current configuration
as a global preset
X&
, Spr
X&]
Command character is a comma.
Example:
8,
Spr08
]
Save current ties as preset 8.
Recall a global preset
X&
. Rpr
X&]
Command character is a period.
Example:
5.
Rpr05
]
Recall preset 5 (becomes the current configuration).
NOTE: X! = Input number (for tie) 00 – (maximum number of inputs for your configuration) (00 = untied)
X@ = Output number 01 – (maximum number of outputs for your configuration)
X$ = SFP or reclockable output 0032 or 72 (00 = global [SFP only])
X% = Output reclocking rate 00 = Bypass mode
01 = Automatic mode (HDSDI [default] only) or N/A (laser) 03 = 2.125 Gbps (laser only)
02 = 1.250 Gbps (laser boards only) 04 = 4.250 Gbps (laser only [default])
X^ = Laser control 0 = disable 1 = enable (default) 2 = automatic
X& = Global preset number 0032 (FOX Matrix 3200) or 64 (FOX Matrix 7200) (00 = current configuration)
FOX Matrix 3200 and 7200 Switchers • Programming Guide 60