Mounting Instructions
If desired, rack mount the switcher as follows:
1. Insert the unit into the rack, aligning the mounting bracket holes with those in the rack.
2. Secure the switcher to the rack using the supplied bolts.
Battery and Power Precautions
The matrix switcher is provided with a permanently installed (factory-soldered in place)
lithium battery. The battery maintains the real time clock in the event of power failure or
extended storage periods and does not affect the normal operation of the switcher. If the
battery becomes ineffective, return the switcher to Extron for repair.
WARNING: There is a danger of explosion if the battery is incorrectly replaced. Do not
attempt to remove or replace the internal battery.
AVERTISSEMENT : Si la pile est mal remplacée, il y a un risque d’explosion. N’essayez
pas de retirer ou de remplacer la batterie interne.
ATTENTION:
This unit uses double pole/neutral fusing. Do not operate the equipment with only
one power supply cord connected.
Cette unité utilise double pôles/fusion neutre. N’utilisez pas l’équipement avec
seulement un cordon d’alimentation connecté.
Removing and Installing an I/O Board or Blank Panel
WARNING: The FOX matrix switchers fiber optic I/O boards output continuous invisible
light (Class 1 rated), which may be harmful to the eyes; use with caution.
Do not look into the fiber optic cable connectors or into the fiber optic cables
themselves.
Plug the attached dust cap into the optical transceiver when the fiber optic cable is
unplugged.
AVERTISSEMENT :
Le grilles de commutation de la gamme FOX cartes d’entrée/
sortie fibre optique émet une lumière invisible en continu (conforme à la classe1) qui
peut être dangereux pour les yeux, à utiliser avec précaution.
Ne regardez pas dans les connecteurs de câble fibre optique sur le panneau arrière
ou dans les câbles fibre optique eux-mêmes.
Branchez la protection contre la poussière dans l’ensemble émetteur/récepteur
lorsque le câble fibre optique est débranché.
NOTES:
As factory configured, the fiber optic I/O boards are either 100 percent singlemode
or 100 percent multimode, but you can remove a fiber optic transceiver module
(one input and one output) of one transmission mode and replace it with a block of
the other transmission mode.
You can mix transmission mode transceiver modules on a fiber optic I/O board,
provided that you ensure that each fiber cable and connected devices are the
appropriate transmission mode for the transceiver module. Typically, singlemode
fiber has a yellow jacket and multimode cable has an orange or aqua jacket.
For proper cooling and air flow, boards or blank panels should be installed in all
locations during normal switcher operations.