User`s manual
FOX 500 Tx/Rx • Remote Control
Remote Control, cont’d
4-10
FOX 500 Tx/Rx • Remote Control
4-11
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional description
Total pixels
N
When the controlling PC is connected to the receiver, the FOX 500 can perform this command only if the fiber 2 cable is connected. The unit
returns the E14 error if fiber 2 is not connected.
Set a total pixel value
11*
X&
# Tpx
X&]
Set the total pixels to a specific value.
Example:
11*15# Tpx+15 Set the total pixel value to 15 pixels larger than the actual
resolution.
Increment total pixel value 11*+#
Tpx
X&]
Increase total pixel value by 1 pixel.
Decrement total pixel value 11*-#
Tpx
X&]
Decrease total pixel value by 1 pixel.
Show total pixel value 11#
Tpx
X&]
List sync frequency
View input frequency 1LS
X*
,
X*]
List the input frequency as
X*
kHz (horizontal) and
X*
Hz (vertical.
Memory presets
Save preset
X(
,
Spr
X(]
Command code is a comma.
Recall preset
X(
.
Rpr
X(]
Command code is a period.
Command/response table for SIS commands (continued)
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional description
Audio input gain and attenuation
N
The set gain (G) and attenuation (g) commands are case sensitive.
N
When the controlling PC is connected to the receiver, the FOX 500 can perform this command only if the fiber 2 cable is not connected. The
unit returns the E14 error if fiber 2 is not connected.
Set input audio gain to
+ dB value
X1)
G Aud
X1@]
Example:
2G
Aud+02.0
]
Set the input audio gain to +2 dB.
Set input audio attenuation
to - dB value
X1!
g Aud
X1@]
Increment level +G
Aud
X1@]
Increase audio level by 1.0 dB.
Example:
+G
Aud+03
]
Increment the audio input level from +2 dB to +3 dB.
Decrement level -G
Aud
X1@]
Decrease the audio level by 1.0 dB.
Example:
-G
Aud-09
]
Decrement audio input level from -08 dB to -9 dB.
Show input gain G
X1@]
Audio output level
Set to consumer level 40*0#
Lvl0
]
Set the transmitter's audio output to the consumer
(–10 dBV) level.
Set to professional level 40*1#
Lvl1
]
Set the transmitter's audio output to the professional
(+4 dBu) level.
Show audio output level 40#
X1#]
0 = consumer, 1 = professional.
Command/response table for SIS commands (continued)