User`s manual
FOX 500 Tx/Rx • Remote Control
Remote Control, cont’d
4-6
FOX 500 Tx/Rx • Remote Control
4-7
Zpg
]
The unit sends the Zpg message whenever all presets have been
erased.
Img
X!]
The unit sends the Img message (with the
X!
variable) whenever
the auto memory function has been toggled on or off.
Img
]
The unit sends the Img message (with no variable) whenever the
auto image function has been triggered.
Tst
X1$]
The unit sends the Tst message whenever a test pattern has been
selected or test patterns are turned off.
1Lnk
X1^
•2Lnk
X1^
•RGB
X1^
•Aud
X1^
]
The unit sends the status message whenever a change in the
fiber link and video and audio connection occurs.
Error responses
When the unit receives a valid SIS command, it executes the
command and sends a response to the host device. If the unit is
unable to execute the command because the command is invalid
or it contains invalid parameters, the unit returns an error
response to the host. The error response codes are:
E10 - Invalid command]
E11 - Invalid preset number]
E13 - Invalid parameter]
E14 - Invalid command for this configuration]
Timeout
Pauses of 10 seconds or longer between command ASCII
characters result in a timeout. The command operation is
aborted with no other indication.
Using the command/response table
The command/response table begins on page 4-8. Lower
case letters are acceptable in the command field except
where indicated for the audio level (gain and attenuation)
commands. Symbols are used throughout the table to represent
variables in the command/response fields. Command and
response examples are shown throughout the table. The ASCII
to HEX conversion table below is for use with the command/
response table.
ASCII to HEX Conversion Table
Space