User`s manual

FOX 500 Tx/Rx • Installation
Installation, cont’d
2-14
FOX 500 Tx/Rx • Installation
2-15
Rear panel serial ports connection
Do not tin the wires!
Controlling
Device
Ground ( )
Receive (Rx)
Transmit (Tx)
Ground ( )
Receive (Rx)
Transmit (Tx)
Bidirectional
RS-232
OVER FIBER
Tx Rx NA
REMOTE
RS-232
ALARM
Tx Rx 1 2
FunctionPin
TX
RX
Gnd
Transmit data
Receive data
Signal ground
NOTE For the RS-232 Over Fiber port, only cross the Tx and
Rx lines once between the source and the target.
Figure 2-9 — RS-232 connectors
N
The RS-232 Over Fiber port is for transmission of serial
signals, such as projector control signals, between the
transmitter and receiver.
The Remote RS-232 port is for remote control of the
transmitter and receiver.
N
The length of exposed wires is critical. The ideal length is
3/16" (5 mm).
If the stripped section of wire is longer than 3/16",
the exposed wires may touch, causing a short circuit
between them.
If the stripped section of wire is shorter than 3/16",
wires can be easily pulled out even if tightly fastened
by the captive screws.
N
The rear panel Remote RS-232 port is active only if the
front panel Configuration port is not in use. If a front
panel configuration connection is made, the Remote
RS-232 port becomes inactive and the front panel
Configuration port is active.
Alarm outputs connection
REMOTE
RS-232
ALARM
Tx Rx 1 2
Pin 1 and pin 2 are
shorted together when
no light is detected.
Do not tin the wires!
Figure 2-10 — Alarms connector
N
The length of exposed wires is critical. The ideal length is
3/16" (5 mm).
If the stripped section of wire is longer than 3/16",
the exposed wires may touch, causing a short circuit
between them.
If the stripped section of wire is shorter than 3/16",
wires can be easily pulled out even if tightly fastened
by the captive screws.
Front panel Configuration ports
FOX 500 Tx
HIGH RESOLUTION FIBER OPTIC RECEIVER
RGB
AUDIO
LINK 1
CONFIG
LINK 2 (OPTIONAL)
FOX 500 Rx
HIGH RESOLUTION FIBER OPTIC RECEIVER
RGB
AUDIO
LINK 1
CONFIG
MENU
NEXT
ADJUST
LINK 2 (OPTIONAL)
16
Figure 2-11 — FOX 500 Tx/Rx front panels
N
These ports are for remote control of the transmitter or
receiver, not for the over fiber RS-232 link.
p
Configuration port — These 2.5 mm mini stereo jacks serve
the same serial communications function as the rear panel
Remote RS-232 ports, but are easier to access than the rear
ports after the units have been installed and cabled. The
optional 9-pin D to 2.5 mm mini jack TRS RS-232 cable,
part #70-335-01 (figure 2-12), can be used for this connection.