im Vertrieb von CAMBOARD Electronics User’s Manual RCP 1000 Remote Control Panel Extron Electronics, USA 1230 South Lewis Street, Anaheim, CA 92805 800.633.9876 714.491.1500 FAX 714.491.1517 USA Extron Electronics, Europe Beeldschermweg 6C, 3821 AH Amersfoort +31.33.453.4040 FAX +31.33.453.4050 The Netherlands Extron Electronics, Asia 135 Joo Seng Rd. #04-01, PM Industrial Bldg. +65.383.4400 FAX +65.383.4664 Singapore 368363 www.camboard.de © 2001 Extron Electronics. All rights reserved.
im Vertrieb von Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
im Vertrieb von CAMBOARD Electronics Table of Contents Chapter 1 • Introduction .......................................................... 1-1 Features ...................................................................................... 1-2 Chapter 2 • Installation ............................................................. 2-1 Rear Panel Connector .......................................................... 2-2 Installation ...............................................................................
imContents, Vertrieb von Table of cont’d CAMBOARD Electronics RCP 1000 Remote Control Panel 1 Chapter One Introduction Features ii www.camboard.de RCP 1000 • Table of Contents Tel. 07131 911201 Fax 07131 911203 ce-info@camboard.
im Vertrieb von Introduction, cont’d Introduction CAMBOARD Electronics The Extron RCP 1000 remote control panel provides complete remote control of the input, effect, and transition controls available on an SGS 408 seamless switcher. Bi-directional communication with the SGS 408 allows a switch to occur from either device while the other device is updated to reflect the switch. RCP 1000 Remote Control Panel Features • Brightness and contrast controls — Adjust the brightness and contrast of an input.
im Vertrieb von Installation, cont’d Installation CAMBOARD Electronics Rear Panel Connector Making an RCP Comm Cable Use the following guidelines to make an RCP cable: • At one end, attach a female 4-pin XLR connector. TO SGS • At the other end, attach a male 4-pin XLR connector. • Connect pins straight through. 1 Figure 2-1 — RCP 1000 rear panel 1 RCP port — One 4-pin XLR connector attaches the RCP 1000 to an SGS 408 seamless switcher.
im Vertrieb von Installation, cont’d CAMBOARD Electronics RCP 1000 Remote Control Panel 3 Chapter Three Operation Top Panel Controls Using the Picture Controls Applying a Switch 2-4 www.camboard.de RCP 1000 • Installation Tel. 07131 911201 Fax 07131 911203 ce-info@camboard.
im Vertrieb Operation, cont’d von Operation CAMBOARD Electronics Top Panel Controls 1 2 3 1 – 8 — Selects the corresponding input to be displayed. Normally, you will not use these buttons during a show. If a program input selection button is pressed, the resulting switch is not seamless. 4 4 SIZE BLACK 1 2 3 4 5 FREEZE BLACK 1 2 3 4 5 6 7 8 CUT 6 7 8 CUT FILTER BRIGHT 1 2 3 4 Take button — Initiates the switch selected by the effects buttons.
im Vertrieb Operation, cont’d von CAMBOARD Electronics Using the Picture Controls The picture controls allow you to adjust the centering (center), sizing (size), filters (filter), and contrast/brightness (cont/bright) of the preview image. Centering an image Press and release the Picture control button until the Center LED lights. 2. To adjust the vertical centering, rotate the left adjustment knob. 3. To adjust the horizontal centering, rotate the right adjustment knob.
im Vertrieb Operation, cont’d von • CAMBOARD Electronics From bottom to top Figure 3-6 — Square wipe effects left to right right to left top to bottom bottom to top • A title can have two effects: window or key. Figure 3-3 — Standard wipe transitions • A curtain wipe causes the preview image to appear to unroll over the program image in two directions simultaneously. A curtain wipe can have either hard (sharp) or soft (fuzzy) edges.
im Vertrieb Operation, cont’d von CAMBOARD Electronics 1. Press the preview input button to display the preview image on the preview monitor. 2. Press the Effect button that has been programmed for the title. (If the button is already lit, you do not need to press it.) 3. The title effect will either be window or key. When you want the title to begin, press the Take button. If the title effect is window, a portion of the program image dissolves to reveal the preview window.
im Vertrieb von cont’d Reference Information, Reference Information CAMBOARD Electronics Installing a Firmware Update To install a firmware update, you may need to replace IC (integrated circuit) U11 or U16, or both. Replacing these ICs may result in loss of presets and other settings. 1. Unplug the RCP comm cable from the rear panel of the RCP 1000. Do not open the cover of the RCP 1000 without unplugging the RCP comm cable. 2.
im Vertrieb von cont’d Reference Information, CAMBOARD Electronics Specifications General Power ............................................ +12VDC, supplied via SGS 408 Temperature/humidity .............. Storage -40° to +158°F (-40° to +70°C) / 10% to 90%, non-condensing Operating +32° to +122°F (0° to +50°C) / 10% to 90%, non-condensing Rack mount .................................. No Enclosure type .............................. Metal Enclosure dimensions ................. 0.8" H x 13.1" W x 7.0" D 2.