DVS 100 and DVS150 Digital Video Scalers 68-459-01 Printed in USA
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock. Warning Power sources • This equipment should be operated only from the power source indicated on the product.
Quick Start — DVS 100 and DVS 150 Installation Step 1 Install the four rubber feet on the bottom of the scaler (1A), or mount the scaler in a rack (1B). Step 2 Turn off power to the input and output devices, and unplug their power cords. Step 3 False front panel uses 2 front holes Attach the scaler to the input devices.
Quick Start — DVS 100 and DVS 150, cont’d Configuring the Scaler Configuring the scaler: Press the input and rate buttons simultaneously, and hold them for two seconds. Stepping through the LCD display menus: Press the input selection button. Changing a selection: Turn the adjustment knob while the menu is displayed. Exiting the menus: Press the input selection button while the Detail menu is displayed, or don’t press any buttons or turn any knobs for eight seconds.
Table of Contents Chapter 1 • Introduction .......................................................................................... 1-1 About the Scaler .................................................................................................... 1-2 Features ..................................................................................................................... 1-2 Chapter 2 • Installation .............................................................................................
Table of Contents, cont’d Chapter 5 • Troubleshooting .................................................................................. 5-1 Operating Problems .............................................................................................. 5-2 Appendix A • Specifications .................................................................................. A-1 Appendix B • Reference Information ................................................................ B-1 Part Numbers ....................
DVS 100 and DVS 150 1 Chapter One Introduction About the Scaler Features
Introduction Introduction, cont’d About the Scaler Each DVS 100 and DVS 150 digital video scaler allows analog video signals (composite video, S-video, and component video) to be displayed on a device with a fixed resolution and aspect ratio, such as an LCD (liquid crystal display) projector, DLP (digital light processing) projector, or plasma display. DVS 150 includes a 15-pin HD RGB pass-through connector for RGB input. Video signals coming into the scaler from this connector are not scaled.
• Output resolutions — Supports the following output resolutions: • 640 x 480 (VGA) at 60 or 75 Hz (Hertz) • 800 x 600 (SVGA) at 60 or 75 Hz • 832 x 624 (Macintosh) at 60 or 75 Hz • 848 x 480 (plasma) at 60 Hz • 852 x 480 (plasma) at 60 or 75 Hz • 1024 x 768 (XGA) at 60 or 75 Hz • 1280 x 768 (plasma) at 56 Hz • 1280 x 1024 (SXGA) at 60 Hz • 1360 x 765 (plasma) at 60 Hz • 480p (HDTV) • 720p (HDTV) • 1080p (HDTV) • Power supply — Includes an internal, 100-240VAC, 50/60 Hz, autoswitchab
Introduction, cont’d 1-4 DVS 100 and DVS 150 Introduction
DVS 100 and DVS 150 2 Chapter Two Installation Rear Panel Features Installation Front Panel Features Configuring the Scaler
Installation Installation, cont’d Rear Panel Features 100-240V 0.3A INPUTS VIDEO OUTPUTS B-Y 1 S-VIDEO R-Y 2 50/60 Hz 2 1 RGB Y 3 4 3 R G B H V S 5 REMOTE 7 6 Figure 1 — DVS 100 rear panel 7 100-240V 0.
Installation Overview To install and set up the DVS 100 or DVS 150, follow these basic steps: 1 If desired, mount the scaler in a rack (see “Mounting the scaler” below). Otherwise, install the rubber feet (see “Installing the rubber feet” on page 2-4). 2 Turn off power to the input and output devices, and unplug the power cables from them. 3 Attach the scaler to the input devices and the output devices. See “Cabling” on page 2-5.
Installation, cont’d False front panel uses 2 front holes INPU T 1 2 3 CO LO R (2) 4-40 x 1/8" Screws TIN T BR IT CO NT RA ST H SH IFT V SH IFT RA TE DIGI TA D L VI VS DE O 100 SC AL ER Use 2 mounting holes on opposite corners Figure 3 — Mounting the scaler Installing the rubber feet The scaler ships with four uninstalled rubber feet. Install the rubber feet only if you are not rack mounting the scaler. To install the rubber feet, do the following: 1.
Cabling The scaler can connect to input devices that produce composite video, S-video, or component video, and to output devices, such as LCD projectors, DLP displays, or plasma displays. The DVS 150 can also connect to input devices that produce RGB video via the RGB passthrough connector. To cable the scaler, complete the following steps. Use figure 5 as a general guide. DVS 100 100-240V 0.
Installation, cont’d If you cable the scaler for sync on green (RGsB or SOG) output, you must also configure the scaler for SOG via the configuration menu. See “Configuring the Scaler” on page 2-7 for instructions. You can install and run two output devices simultaneously, one using BNC connectors, and the other using the RGB connector.
7 Contrast control button — Allows you to adjust the image contrast. For more information, see “Adjusting an image” on page 3-2. 8 Horizontal shift control button — Allows you to adjust the horizontal shift. For more information, see “Adjusting an image” on page 3-2. 9 Vertical shift control button — Allows you to adjust the vertical shift. For more information, see “Adjusting an image” on page 3-2. 10 Output rate control button — Allows you to choose the output rate.
Installation, cont’d Vertical sync polarity (V-SYNC) — Changes the polarity of the vertical sync signal to allow any projector to distinguish the DVS 100 input from a standard RGB input. To toggle between Positive and Negative, turn the adjustment knob while the Vertical sync menu is displayed. By default, the vertical sync polarity is set to Negative. Sync on green (SOG) — If set to Yes, provides sync on green (RGsB or SOG) output.
DVS 100 and DVS 150 3 Chapter Three Operation Front Panel Operations
Operation Operation, cont’d Front Panel Operations The front panel includes an LCD screen that displays the current status of the scaler and the scan rate of the current video input signal. You can also use controls on the front panel to control the image display. Diagrams of the front panels are shown on page 2-6. Default screens By default, the LCD toggles between two screens every four seconds.
press the same button again or if you stop turning the knob for eight seconds. If an image control reaches its minimum, maximum, or default level, the LCD displays a screen similar to the screens shown in figure 13. COLOR Min COLOR Default COLOR Max Figure 13 — Minimum, maximum, and default value screens If input 4 (RGB pass-through) of the DVS 150 is selected, you cannot adjust the image through the scaler. Color control button — Adjusts the color intensity.
Operation, cont’d Freeze mode Freeze mode locks the output display to the current image. Freeze mode can be activated only by issuing an RS-232 command IMAGE (see chapter 4 for more information). If freeze mode FROZEN is activated, the LCD screen displays the message displayed at the left. If input 4 (RGB pass-through) of the DVS 150 is selected, you cannot activate freeze mode.
System reset To perform a system reset, press and hold the input selection button while attaching the AC power cord. The picture SYSTEM control settings for all input sources, the output rates, RESET and the configuration options are reset to their factory default settings. The LCD displays the message at the left for four seconds, and then changes back to the default screens.
Operation, cont’d 3-6 DVS 100 and DVS 150 Operation
DVS 100 and DVS 150 4 Chapter Four Serial Communication RS-232 Programmer’s Guide Remote Contact Closure Operation Control Software for Windows
Serial Communication Serial Communication, cont’d The scaler’s RS-232 connector can be connected to the serial port output of a host device such as a computer or control system. This connection makes software control of the scaler possible. Figure 14 shows a scaler RS-232 connection to a host serial port connector.
RS-232 Programmer’s Guide DVS initiated messages When a local event occurs, such as a front panel operation, the scaler responds by sending a message to the host. The DVS-initiated messages are listed below (underlined). (C) Copyright 1999, Extron Electronics, DVS xxx, Vx.x The copyright message is initiated by the scaler when it is first powered on. DVS xxx is the scaler model, and Vx.xx is the firmware version number.
Serial Communication, cont’d Command/response table Symbol definitions: = CR/LF, • = space = Inputs = 1 = Composite 2 = Component 3 = S-video 4 = RGB (DVS 150 only) = Adjustment range 1-127 = Output rate = 1 = 640x480 @ 60 Hz 2 = 640x480 @ 75 Hz 3 = 800x600 @ 60 Hz 4 = 800x600 @ 75 Hz 5 = 832x624 @ 60 Hz 6 = 832x624 @ 75 Hz 7 = 852x480 @ 60 Hz 8 = 852x480 @ 75 Hz 9 = 1024x768 @ 60 Hz 10 = 1024x768 @ 75 Hz 11 = 1280x1024 @ 60 Hz 12 = 480p 13 = 720p 14 = 1080p 15 = 848x480 @ 60 Hz 16 = 1280x768 @ 56 Hz 17 = 1
COMMAND Vertical shift Specific value Increment up Increment down ASCII RESPONSE DESCRIPTION / Vph Vph+ Vph– Selects vertical shift Shift image up one step Shift image down one step = Rte Set the video output rate F f Frz 1 Frz Ø Set freeze mode to On (freeze current displayed image) Set freeze mode to Off X x Exe 1 Exe Ø Set executive mode to On Set executive mode to Off {/ }/ Set output rate Freeze Enable Disable Executive mode Enable Disable Query software version q Q (Same as Q below
Serial Communication, cont’d Using the software 1. To run the Signal Enhancement Products Control Program, doubleclick on the Signal Enhancement Products Control Pgm icon in the Extron Electronics group or folder. The Comm menu appears on the screen. 2. Click on the comm port that is connected to the scaler’s RS-232 port. The Extron Signal Enhancement Products Control Program window appears. It displays the current settings and input type detected (see figure 15).
DVS 100 and DVS 150 5 Chapter Five Troubleshooting Operating Problems
Troubleshooting Troubleshooting, cont’d This section gives recommendations on what to do if you have problems operating the DVS 100 or DVS 150, and it provides examples and descriptions for some image problems you might encounter. Following are some tips to help you in troubleshooting. 1. Some symptoms may resemble others, so you may want to look through all of the examples before attacking the problem. 2. Be prepared to backtrack in case the action taken doesn’t solve the problem. 3.
Problem Cause Solution Picture controls are not active. Input 4 is selected (DVS 150 only). Switch to input 1–3. Input 4 is pass-through only (page 1-2). The image is green. The unit is configured for sync on green. Turn off sync on green (page 2-8). The image is too soft. The detail level Change the detail level needs to be changed. (page 2-8).
Troubleshooting, cont’d 5-4 DVS 100 and DVS 150 Troubleshooting
DVS 100 and DVS 150 A Appendix A Specifications
Specifications Video input Number/type ............................... 1 composite video, 1 S-video, 1 component video (R-Y, B-Y, Y); 1 RGB pass-through (DVS 150 only) Connectors .................................... 3 BNC female .......................... component video 1 4-pin mini-DIN female ...... S-video 1 BNC female .......................... composite video 1 15-pin HD female ............... RGB pass-through (DVS 150 only) Nominal level(s) .......................... Analog — 0.7V to 1.
DVS 100 and DVS 150 B Appendix B Reference Information Part Numbers Glossary
Reference Information Reference Information, cont’d Part Numbers DVS 100 and DVS 150 part numbers Extron Part Part # DVS 100 DVS 150 Signal Enhancement Products Control Program DVS 100 and DVS 150 User’s Manual S-video cable, 6’ 60-304-01 60-317-01 29-017-01 68-459-01 26-316-02 Related part numbers Extron Part Part # Universal rack shelf 60-190-01 BNC cables Extron SHR BNC cables are super-high resolution cables.
Pre-cut cables BNC-4 HR cable is used for RGBS cable runs, and BNC-5 is used for RGBHV cable runs. Either type can also be used for RGsB (sync on green). All Extron BNC cables have male gender connectors at both ends. A plenum version of the BNC-5 HR cable is also available. BNC-4 HR Cable BNC-4-25’ HR (25 feet/7.5 meters) BNC-4-50’ HR (50 feet/15.0 meters) BNC-4-75’ HR (75 feet/23.0 meters) BNC-4-100’ HR (100 feet/30.0 meters) BNC-4-150’ HR (150 feet/45.0 meters) BNC-4-200’ HR (200 feet/60.
Reference Information, cont’d Scaling — Changes the size of an image without changing its shape. Scaling can be used when the image size does not fit the display device. A digital video scaler converts an NTSC, PAL, or SECAM image to a size that can be displayed on a device with a fixed resolution and aspect ratio, such as an LCD (liquid crystal display) projectors, DLP (digital light processing) projectors, or plasma projector .
FCC Class B Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
EXTRON ELECTRONICS/RGB SYSTEMS, INC. 1230 South Lewis Street, Anaheim, CA 92805 800.633.9876 714.491.1500 FAX 714.491.1517 U.S.A. EXTRON ELECTRONICS, EUROPE Beeldschermweg 6C, 3821 AH Amersfoort +31.33.453.4040 FAX +31.33.453.4050 The Netherlands EXTRON ELECTRONICS, ASIA 41B Kreta Ayer Road, Singapore 089003 +65.226.0015 FAX +65.226.0019 Singapore EXTRON ELECTRONIC INFORMATION EXTRONWEB™: www.extron.com EXTRONFAX™: 714.491.