User's Manual Owner's manual
DVCM 50 • Software-based Confi guration and Control
5-2
Software-based Confi guration and Control
PRELIMINARY
The DVCM 50 can be remotely confi gured via a host computer connected to the 
front panel confi guration port. Through this port, you can program the DVCM’s 
buttons with commands by using the Windows
®
-based confi guration software 
(MLC 52/DVCM 50 Control Program). The optional 9-pin D to 2.5 mm stereo mini 
TRS RS-232 cable (part #70-335-01) can be used for this connection. 
The connector has the following pin assignments:
6 feet 
(1.8 m) 
Part #70-335-01 
5 
1 
9 
6 
Sleeve (Gnd) 
Ring 
Tip 
 9-pin D  Connection  TRS Plug 
  Pin 2  Computer's RX line  Tip 
 Pin 3  Computer's TX line  Ring 
  Pin 5  Computer's signal ground  Sleeve 
Computer 
DVCM 50 
DVD & VCR CONTROL 
PLAY NEXT/FWD PAUSE  STOP 
TUNER 
Tx 
PREV/REW 
ENTER 
TITLE  MENU 
TV/VCR 
DVD VCR 
CONFIG
DVCM 50 
To Front Panel 
Config Port 
RS-232 confi guration cable pin assignments
The DVCM 50 uses the following protocol:
9600 baud   1 stop bit 
8 bits    Flow control: None
Parity: None
Using the Windows
®
-based Confi guration Software
Extron’s MLC 52/DVCM 50 Control Program Windows-based confi guration 
software, included with your DVCM 50, provides a convenient way to program all 
the DVCM buttons, in both DVD and VCR mode. This confi guration program’s 
graphical user interface includes the same functions as those on the DVCM’s front 
panel, plus the ability to download IR drivers for a wide range of A/V devices.
  This software program only confi gures the DVCM 50 buttons. It does not 
control the DVCM itself. In other words, you are not able to click buttons on 
the screen to make the DVCM switch modes, start or stop the VCR, etc.
To install and run the DVCM 50 confi guration program software, ensure that your 
PC meets the following minimum requirements:
•  Windows 2000, XP, or higher
• 400 MHz processor
•  32 MB free hard disk space
Extron’s Windows-based confi guration software is provided on CD with the 
DVCM, and updates can be downloaded from the Extron Web site (http://www.
extron.com).
In order to use the confi guration software with the DVCM, your PC must 
be connected to the DVCM 50 front panel confi guration port by the optional 
9D-2.5 mm TRS serial cable, described above.