Setup guide

2
DTP T FB 332 and DTP T FB 232 • Setup Guide (Continued)
Step 3 — Make side panel connections under the adapter plates and set the
TP function switch
A
Power (see figure 1 on page 1) — Connect the included 12 VDC power supply to either unit,
transmitter or receiver, as shown at right. Use the included tie-wrap to strap the cord to the
captive screw connector.
Connect an IEC power cord between the power supply and a 100-240 VAC, 50-60 Hz source.
NOTE: If the TP switch (
C
) is in DTP, one power supply can power both units.
If the switch is in HDBT, each unit requires its own power supply.
B
Remote RS-232 port — For serial RS-232 control, connect a host device or control system to
the 3.5 mm, 3-pole captive screw connector. The wiring and protocol are shown at right.
C
TP function switch
If the receiving device is in the Extron DTP series, set this switch to DTP. The TP output
consists of HDMI with embedded audio, analog audio, RS-232 and IR, and remote power. The
transmitter and receiver can be powered by one 12 VDC power supply connected to either unit.
For an HDBaseT-enabled receiver type, set this switch to HDBT position. The TP output consists of HDMI with embedded audio plus
RS-232 and IR. The transmitter and receiver each requires its own 12 VDC power supply.
ATTENTION:
Position this switch BEFORE connecting the appropriate device to the TP connector. Failure to comply can damage the
endpoint.
Positionnez le sélecteur AVANT de connecter l’appareil approprié au connecteur TP. Ne pas respecter cette procédure
pourrait endommager le point de connexion.
D
Out port— Connect the Out (RJ-45) port to the DTP In port on the receiver. Extron recommends that you terminate both cable ends in
accordance with the following, at a minimum: TIA/EIA T 568B and 24 AWG, solid conductor, shielded cable with 400 MHz bandwidth.
ATTENTION:
Do not connect this connector to a computer data or telecommunications network.
Ne connectez pas ces port à des données informatiques ou à un réseau de télécommunications.
Signal LED indicator — Lights when the device is transmitting a video signal or a test pattern.
Link LED indicator — Lights when a valid link between a DTP or HDBT input and output is established.
Step 4 — Mount the unit in the floor box
a. Place the DTP T FB unit in the desired position in the oor box so that the side panel connectors face
towards the opening of the oor box.
ATTENTION:
Ensure there is enough space between the top panel connectors and the lid of the oor box so the lid fully closes.
Assurez vous qu’il y ait assez d’espace entre les connecteurs du panneau supérieur et le couvercle du boîtier de sol an
que celui-ci puisse se fermer entièrement.
b. Using the provided self-threading screws, secure the DTP T FB unit to the adapter plates (see gures 2 through 5).
Ackermann GB3 (OBO Betterman) floor box
DTP T FB 332
POWER
DTP T FB 332
REMOTE
RS-232
- +
G
Rx
Tx
12V
A MAX
XTP OUT
NOTE: For position 2, install
adapter plate 995242 to
one of the other adapter
plates.
995242
995241
Figure 2. DTP T FB Unit in an Ackermann GB3 (OBO Betterman) Floor Box
Power Supply
Output Cord
Ridges
Smooth
Captive
Screw
Connector
3"
16 (5 mm) MAX
SECTION A–A
AA
RxTx Gnd
RS-232 De
vice
9600 Baud
8 data bits
No parity 1 stop bit
G
REMOTE
RS-232
Rx
Tx
3"
16 (5 mm) MAX
5
Pin
1
2
3
6
7
8
4
Wire color
White-green
Green
White-orange
White-blue
Orange
White-brown
Brown
Blue
TIA/EIA T
568B
TP Wires
12345678
Pins: