Setup guide
2
DTP T FB 332 and DTP T FB 232 • Setup Guide (Continued)
Step 3 — Make side panel connections under the adapter plates and set the
TP function switch
A
Power (see figure 1 on page 1) — Connect the included 12 VDC power supply to either unit,
transmitter or receiver, as shown at right. Use the included tie-wrap to strap the cord to the
captive screw connector.
Connect an IEC power cord between the power supply and a 100-240 VAC, 50-60 Hz source.
NOTE: If the TP switch (
C
) is in DTP, one power supply can power both units.
If the switch is in HDBT, each unit requires its own power supply.
B
Remote RS-232 port — For serial RS-232 control, connect a host device or control system to
the 3.5 mm, 3-pole captive screw connector. The wiring and protocol are shown at right.
C
TP function switch —
If the receiving device is in the Extron DTP series, set this switch to DTP. The TP output
consists of HDMI with embedded audio, analog audio, RS-232 and IR, and remote power. The
transmitter and receiver can be powered by one 12 VDC power supply connected to either unit.
For an HDBaseT-enabled receiver type, set this switch to HDBT position. The TP output consists of HDMI with embedded audio plus
RS-232 and IR. The transmitter and receiver each requires its own 12 VDC power supply.
ATTENTION:
• Position this switch BEFORE connecting the appropriate device to the TP connector. Failure to comply can damage the
endpoint.
• Positionnez le sélecteur AVANT de connecter l’appareil approprié au connecteur TP. Ne pas respecter cette procédure
pourrait endommager le point de connexion.
D
Out port— Connect the Out (RJ-45) port to the DTP In port on the receiver. Extron recommends that you terminate both cable ends in
accordance with the following, at a minimum: TIA/EIA T 568B and 24 AWG, solid conductor, shielded cable with 400 MHz bandwidth.
ATTENTION:
• Do not connect this connector to a computer data or telecommunications network.
• Ne connectez pas ces port à des données informatiques ou à un réseau de télécommunications.
Signal LED indicator — Lights when the device is transmitting a video signal or a test pattern.
Link LED indicator — Lights when a valid link between a DTP or HDBT input and output is established.
Step 4 — Mount the unit in the floor box
a. Place the DTP T FB unit in the desired position in the oor box so that the side panel connectors face
towards the opening of the oor box.
ATTENTION:
• Ensure there is enough space between the top panel connectors and the lid of the oor box so the lid fully closes.
• Assurez vous qu’il y ait assez d’espace entre les connecteurs du panneau supérieur et le couvercle du boîtier de sol an
que celui-ci puisse se fermer entièrement.
b. Using the provided self-threading screws, secure the DTP T FB unit to the adapter plates (see gures 2 through 5).
Ackermann GB3 (OBO Betterman) floor box
DTP T FB 332
POWER
DTP T FB 332
REMOTE
RS-232
- +
G
Rx
Tx
12V
A MAX
XTP OUT
NOTE: For position 2, install
adapter plate 995242 to
one of the other adapter
plates.
995242
995241
Figure 2. DTP T FB Unit in an Ackermann GB3 (OBO Betterman) Floor Box
Power Supply
Output Cord
Ridges
Smooth
Captive
Screw
Connector
3"
16 (5 mm) MAX
SECTION A–A
AA
RxTx Gnd
RS-232 De
vice
• 9600 Baud •
8 data bits
• No parity • 1 stop bit
G
REMOTE
RS-232
Rx
Tx
3"
16 (5 mm) MAX
5
Pin
1
2
3
6
7
8
4
Wire color
White-green
Green
White-orange
White-blue
Orange
White-brown
Brown
Blue
TIA/EIA T
568B
TP Wires
12345678
Pins: