Setup guide
Figure 3. DMS 1600 Switcher Rear Panel
ANAHEIM, CA
RESET
RS232/RS422
REMOTE
LAN
ACT
LINK
REDUNDANT
PRIMARY
PRIMARY POWER SUPPLY
REDUNDANT POWER SUPPLY
FAN ASSIMBLY
FAN ASSIMBLY
100-240V
50-60Hz
2.5A MAX.
100-240V
50-60Hz
2.5A MAX.
DISCONNECT BOTH POWER
CORDS BEFORE SERVICING
N
1 - 4
5 - 8
9 - 12
13- 16
17 - 20
21 - 24
25 - 28
29- 32
33 - 36
A B
DVI-D INPUTS DVI-D OUTPUTS
C D A B C D
A B
DVI-D INPUTS DVI-D OUTPUTS
C D A B C D
A B
DVI-D INPUTS DVI-D OUTPUTS
C D A B C D
DVI-D OUTPUTS
A B C D
DVI-D OUTPUTS
A B C D
DVI-D OUTPUTS
A B C D
DVI-D OUTPUTS
A B C D
7 3 4 5 7
21
6
8
Figure 4. DMS 3600 Switcher Rear Panel
Making Connections
a
DVI-I Input connectors — Connect DVI cables between these ports
and the DVI output ports of the digital video sources.
b
DVI-I Output connectors — Connect DVI displays for the routed
direct digital image.
c
Remote port — If desired, connect a control system or computer
to the rear panel Remote RS-232/RS-422 port.
RS-232 Function Pin Function
1
2
3
4
5
6
7
8
9
—
Tx
Rx
—
Gnd
—
—
—
—
Not used
Transmit
Receive
Not used
Ground
Not used
Not used
Not used
Not used
—
Tx–
Rx–
—
Gnd
—
Rx+
Tx+
—
Not used
Transmit (–)
Receive (–)
Not used
Ground
Not used
Receive (+)
Transmit (+)
Not used
RS-422
5
1
96
Figure 5. Remote RS-232/RS-422 Output Connector Wiring
d
Ethernet port (LAN connector) — If desired, connect a network
WAN or LAN hub, a control system, or a computer to the Ethernet
RJ-45 port.
Network connection —
Wire as a patch (straight-through) cable.
Computer or control system connection — Wire the interface
cable as a crossover cable.
NOTE: The factory default IP address is 192.168.254.254.
e
Reset button — Initiates four levels of reset of the matrix switcher.
For different reset levels, press and hold the recessed button while
the switcher is running or while you power up the switcher.
See the DMS 1600 and DMS 3600 User Guide, available on the
Extron DVD or at www.extron.com.
f
Power connectors — Plug the switcher into two grounded AC
sources.
NOTE: For reliability, connect the power cord from the
Redundant power connector to either an
uninterruptible power source or to a power source
that is completely independent of the primary power
source.
g
Primary and Redundant power supply indicator LEDs —
Green —
Indicates that the associated power supply is operating
within normal tolerances.
Red —
Indicates that the associated power supply is operating
outside the normal tolerances or has failed. See "Removing and
Installing a Power Supply Module" to replace the power supply.
h
Fans — See "Removing and Installing a Fan".
ANAHEIM, CA
RESET
REMOTE
RS-232/RS-422
LAN
ACT LINK
REDUNDANT
100-240V
50-60Hz
1.2A MAX.
PRIMARY
100-240V
50-60Hz
1.2A MAX.
DISCONNECT BOTH POWER
CORDS BEFORE SERVICING
PRIMARY POWER SUPPLY
REDUNDANT POWER SUPPLY
1 - 4
5 - 8
9 - 12
13 - 16
A B
DVI-D INPUTS DVI-D OUTPUTS
C D A B C D
DVI-D INPUTS
A B
DVI-D INPUTS DVI-D OUTPUTS
C D A B C D
DVI-D INPUTS
3
4
7 7
21
5
6
8
REDUNDANT
100-240V
50-60Hz
1.2A MAX.
PRIMARY
100-240V
50-60Hz
1.2A MAX.
DISCONNECT BOTH POWER
CORDS BEFORE SERVICING
6 DMS 1600 and DMS 3600 • Installation 7DMS 1600 and DMS 3600 • Installation