Command ASCII Command
(Host to Unit)
Response
(Unit to Host)
Additional Description
Save, recall, and directly write presets
NOTES:
If you try to recall a preset that is not saved (does not exist), the matrix switcher responds with the error code
E11
.
The following characters are invalid or not recommended in preset names: = - , “ @ = [ ] { } “ ; : | \ and ?.
If a room is not defined (does not exist in the switcher) and you try to save a room preset, the matrix switcher responds with error
code
E11
.
A room can contain a maximum of 16 outputs.
An output can belong only to one room.
The maximum number of rooms (
X&
) is 10.
The default name (
X*
) is the room number with four trailing spaces: “
Room
#
X&
••••.”
Save current configuration
as a global preset
X^
, Spr
X^]
Command character is a comma.
Example:
9, Spr09]
Save current configuration as preset 9.
Recall a global preset
X^
. Rpr
X^]
Command character is a period.
Example:
5. Rpr05]
Recall preset 5 to become the current
configuration.
Direct write process for a global preset —
NOTE: The direct write of a global preset should always be preceded by a clear global preset ties command of that same preset
number, as shown below. In a directly-written preset, the input tied to each output (or no tied input) remains unchanged unless
overwritten or cleared.
If you do not clear the ties in a global preset number before you directly write a global preset to that number, ties that are part of the
previous version of the specified preset with the same number can unexpectedly become part of the newly-created preset.
Clear all ties of a preset
E
+
X^
P0*!
}
Spr
X^]
Clear all ties in preset
X^
.
Directly write a global preset
E
+
X^
P
X!
*
X@
!
X!
*
X@
&
X!
*
X@
%...
X!
*
X@
!
}
Enter as many ties as are valid for this
configuration. The ! tie command, &
tie command, and % tie command are
interchangeable.
Spr
X^]
Example:
E
+27P0!
}
Spr27
]
Clear all ties in preset 27.
+27P12*5!10*09%3*2!3*8&
Esc
Brackets are shown to separate ties for clarity
only. Create global preset 27, which ties input
12 to output 5, input 10 to output 9, input 3 to
output 2, and input 3 to output 8.
Spr27
]
Write room outputs
EX&
,
X@
1
,
X@
2
,...
X@
n
MR
}
Mpr
X&
,
X@
1
,
X@
2
,...
X@
n
]
See notes above.
Example:
E
8,3,04,5,6MR
}
Mpr8,03,04,05,06
]
Outputs 3, 4, 5, and 6 are assigned to room 8.
Read room outputs
EX&
MR
} X*
,
X@
1
,
X@
2
,
X@
n
]
Example:
E
3MR
}
Room•#03••••,01,02,08,09
]
Outputs 1, 2, 8, and 9 are assigned to room 3.
Save current configuration
as a room preset
X&
*
X(
, Rmm
X&
Spr
X(]
Command character is a comma.
Example:
3*9,
Rmm03Spr09
]
Save current configuration as preset 9 for room 3.
Recall room preset
X&
*
X(
. Rmm
X&
Rpr
X(]
Command character is a period.
Directly write a room preset
E
+
X&
*
X(
P
X!
*
X@
!
X!
*
X@
&
X!
*
X@
%...
X!
*
X@
!
}
Enter as many ties as are valid for this
configuration. The ! tie command, &
tie command, and % tie command are
interchangeable.
Rmm
X&
Spr
X(]
Example:
+7*3P12*7&11*5&4*15%6*6!
Esc
Brackets are shown to separate ties for clarity
only. Create preset 3 for room 7, which ties
input 12 to output 7, input 11 to output 5,
input 4 to output 15, and input 6 to output 6.
Rmm07Spr03
]
NOTE: X! = Input number (for tie) 0016 (20, 32, 36) (00 = untied)
X@ = Output number 0116 (20, 32, 36)
X^ = Global preset number 00 through 32
X& = Room number (for room presets) 01 through 10 (each can have up to 10 room presets [X(s] assigned)
X* = Name Up to 12 upper-and lower-case alphanumeric characters are valid
X( = Room preset number 00 through 10