User Guide Manual
Reinitialize Digital I/O
Should the script stop running for any reason, select Tools > Configure Digital I/O, 
then select Reinitialize Digital I/O. This option is only available in Live mode.
To remove a digital I/O script from the DMP64:
Only one digital I/O configuration can be active at a time. If the I/O activity needs to be 
modified, remove the current configuration by:
1.  From the Tools menu, click Configure Digital I/O, then select Remove Digital 
I/O Configuration from the Device and click OK.
2.  If the DSP Configurator is connected to a device, the I/O configuration is removed. If it 
is not connected, a connection dialog box appears. 
3.  Make certain the connection information is correct, then press OK. The I/O 
configuration script is removed and a confirmation dialog box will appear. 
Emulate Mode and Live Mode
The DSP Configurator program has two operational modes, Live and Emulate. In 
Live mode, the program has established a connection and is synced with the DMP64. 
Changes affect the device in real-time and changes in the current state of the device are 
reflected in the DSP Configurator. In contrast, Emulate mode allows the user to work 
offline, creating or editing configurations that do not immediately affect DMP64 operation.
The DSP Configurator program always starts in Emulate mode. All functions of the 
DSPConfigurator program are available without connecting to the DMP64. The user 
can build a configuration from the blank screen, or open an existing file that contains the 
last configuration displayed plus saved presets. All settings and adjustments are saved 
to a configuration file on the PC. When the saved file is opened in the DSPConfigurator 
program, the program restores all settings as the current configuration (emulated if in 
Emulate mode or live if in Live mode).
Live mode can be entered at any time after program launch, either with a blank 
configuration, after creating a configuration, or after loading a previously saved 
configuration file. 
In Emulate mode, the current state is titled Current Emulation. In Live mode, the 
current state is titled, Current State. 
Synchronizing: Pull From or Push To the DMP64
When switching to Live mode after making changes to the current configuration in 
Emulate mode, either:
• Pull data from the device and update the DSP Configurator program configuration. 
This option downloads device settings from the DMP64 and synchronizes it with the 
DSP Configurator program overwriting the current DSPConfigurator settings, or
• Push data from the DSPConfigurator program to the device, overwriting settings in 
the DMP64.
Live mode can also be used to tailor audio settings in real time while listening to the 
audio output.
DMP64 • Software Control 76