User`s manual

CVEQ 100 & SVEQ 100 • Quick Start Guide
Quick Start Guide — CVEQ & SVEQ, cont’d
QS-2 TOC-i
CVEQ 100 & SVEQ 100 • Table of Contents
Table of Contents
68-1252-01 Rev. B
01 07
All trademarks mentioned in this manual are the properties of their respective owners.
CVEQ 100
GAIN
EQ
Chapter One • Introduction .............................................1-1
About this Manual .................................................................... 1-2
About the CVEQ 100 and SVEQ 100 .................................... 1-2
Models .................................................................................... 1-2
Features .................................................................................. 1-2
Connection diagram example ............................................... 1-3
Chapter Two • Installation and Operation ................... 2-1
Mounting the CVEQ 100 and SVEQ 100 ............................. 2-2
Tabletop use ........................................................................... 2-2
UL rack mounting requirements ........................................... 2-2
Rack mounting ....................................................................... 2-3
Furniture mounting — under-desk ....................................... 2-5
Furniture mounting — through-desk (CVEQ 100 only) ....... 2-6
Back of the rack mounting (SVEQ 100 only) ........................ 2-7
Rear Panel Features and Cabling .......................................... 2-9
Power supply wiring ............................................................ 2-10
Front Panel Features and Operation ................................. 2-12
Gain adjustment control ......................................................
2-13
Equalization (EQ)
adjustment control ................................ 2-13
Appendix A • Specifications, Part Numbers, and
Accessories
........................................................................................A-1
Specifications ..............................................................................A-2
Included Parts .............................................................................A-5
CVEQ 100/SVEQ 100 Mounting Accessories ......................A-5
Cables and Adapters .................................................................A-5
Step 5
Connect power cords and turn on the output devices (projector/
monitor, speakers), and input devices.
Step 6
The picture should appear, and sound should be audible. If not,
ensure that all devices are plugged in and receiving power. Check
the cabling; make adjustments as needed.
Step 7
While watching the display, adjust the video gain and equalization
by using the rotary Gain and Equalize (EQ) controls. An oscilloscope
can be used to achieve a more precise adjustment. See “Front Panel
Features and Operation” in chapter 2.
Step 8
Adjust the potentiometers for the outputs, using an Extron Tweeker.
If using very short output cables, set all pots to the default
setting (the arrow on the pot pointing to the dot beside it; see the
illustrations below).
If using long cables, follow these steps:
a. Supply the Color Bars test signal to the input.
(Recommendation: Use an Extron VTG 300 Video Test Generator
to generate the test signal.)
b. Adjust the Gain pot(s) for the output until the signal level at the
far end is the same as the input (or the display shows the correct
brightness and contrast).
c. Adjust the EQ pot for the output so that no overshoot or round
front corner appears at the far end on the scope (or you see a
sharp picture with no smearing).