CTL101 CONTROL INTERFACE CTL101 OPERATION MANUAL
Installation and Safety Instructions For Models without a Power Switch: The socket outlet shall be installed near the equipment and shall be accessible. For all Models: No serviceable parts inside the unit. Refer service to a qualified technician. For Models with Internal or External Fuses: For continued protection against fire hazard, replace only with same type and rating of fuse.
CTL101 QUICK START This section provides basic, step-by-step directions for installing the CTL101 Control Interface. Additional instructions can be found on page 3, and Application Diagrams are provided on pages 7 - 11. 1. Set the Dipswitches (if applicable). Dipswitch settings are discussed on pages 13 & 14. 2. Install the CTL101 Interface at the desired location, making sure that the IR sensor window remains unobstructed (available mounting hardware is listed on page 24). 3.
1 Table of Contents Product Overview.................................................................................................2 Description ........................................................................................................2 Product Features ................................................................................................2 Installation ............................................................................................................
2 Product Overview DESCRIPTION The CTL101 interface converts contact closures and infrared (IR) signals to RS-232, RS-422 or RS-485 serial commands. The unit allows complete systems integration and system control via a single computer workstation, contact closure and / or infrared remote. The CTL101 can also be used to remotely control a VCR, DVD, INLINE unit or any other IR receiver equipped device by passing along IR remote signals.
3 Installation This section offers step-by-step instructions for installing the CTL101 Control Interface. Serial Port Wiring Diagrams are provided on pages 4 - 6, Application Diagrams are included on pages 7 - 11, and a Front and Rear Panel Connectors and Controls Diagram can be found on page 13. All connectors and controls are located on the back of the unit. Note: Installation of the CTL101 must only be carried out by qualified technicians.
4 Diagram D on page 10). The mouse type emitter attaches directly over the IR sensor of the device being controlled (when used to control a single unit) or can be mounted up to three feet away from the IR controlled devices when used to control multiple units. Note: Emitters are to be used for local control of video equipment only (i.e. the video equipment and the CTL101 are in the same room).
5 Full Duplex RS-422/485 Menu Setup: Select Full Duplex Mode for Applicable Ports SW Bank 1 Input Port: Switch 1-3 set to 1 Output Port: Switch 4-6 set to 1 CTL101 Serial Port Computer Serial Port (DB-9 Connector) (A) TX+ 3 3 RX+ (A) (B) TX- 2 7 RX- (B) (A) RX+ 5 2 TX+ (A) (B) RX- 4 6 TX- (B) GND 1 5 GND 1 GND TX+ 120 ohm termination RX+ 120 ohm termination Input SW 2 Output SW 5 Input SW 3 Output SW 6 TX- RX- Note: In Full Duplex Mode, terminate both TX and RX lines.
6 CTL131 Remote Sensor Set switch on rear of CTL101 to “EXT” CTL101 IR Sensor Input CTL131 GND 1 1 RCV - 2 2 RCV+ 3 3 +5V 4 4 CAUTION: Pay close attention NOT to reverse the +5V and GND connections. Pin 1 and 4 are marked on the circuit board next to the connector. 0 to 500ft use 20 AWG min, 500 to 1000ft use 18 AWG min.
CTL101 CONTROL INTERFACE APPLICATION DIAGRAM A serial control sources Control System contact closure sources IN9471 Module With Double Throw Switch PC IN9360 Module With Switch Switch IN3590 Wired Remote ir controlled DVD Player with IR Control CTL130 IR Emitter CTL101 Back View T E C H N I C A L S U P P O R T : (800) 882-7117 (714) 921-4100 MADE IN U.S.A www.inlineinc.com IR SENSOR INPUT 9 0-2 60 VA C; 0. 05 A; 47- 63Hz CONTACT CLOSURE IR OUT + – EXT INT SENSOR MODE FUSE: 0.
CTL101 CONTROL INTERFACE APPLICATION DIAGRAM B: IR to Serial Command Conversion serially controlled devices IN1404 Video / RGB Video Scaler with RS-232 Serial Control Port = IR Signal = Serial Control = Power IN31608–6 Presentation Switcher with RS-232 Serial Control Port RS232 or RS422 or RS485 CTL101 Back View T E C H N I C A L S U P P O R T : (800) 882-7117 (714) 921-4100 MADE IN U.S.A www.inlineinc.com IR SENSOR INPUT 9 0-2 60 VA C; 0.
CTL101 CONTROL INTERFACE APPLICATION DIAGRAM C: Contact Closure to Serial Command Conversion contact closure sources IN9471 Module With Double Throw Switch CTL101 Back View T E C H N I C A L S U P P O R T : (800) 882-7117 (714) 921-4100 MADE IN U.S.A www.inlineinc.com IR SENSOR INPUT IN9360 Module With Switch Switch = Serial Control = Contact Closure = Power IN3590 Wired Remote 9 0-2 60 VA C; 0. 05 A; 47- 63Hz CONTACT CLOSURE IR OUT + – EXT INT SENSOR MODE FUSE: 0.
CTL101 CONTROL INTERFACE APPLICATION DIAGRAM D: Remote IR Sensor / IR Repeating = = = = IR Signal 4 Conductor 20 AWG Hard-Wired IR Signal Power CTL101 — Back View T E C H N I C A L S U P P O R T : (800) 882-7117 (714) 921-4100 MADE IN U.S.A www.inlineinc.com IR SENSOR INPUT 9 0-2 60 VA C; 0. 05 A; 47- 63Hz CONTACT CLOSURE IR OUT + – EXT INT SENSOR MODE A/C Power Source FUSE: 0.
CTL101 CONTROL INTERFACE APPLICATION DIAGRAM E: Serial Command Conversion / Long Distance Transmission serial control sources Control System = Serial Control = Power PC RS232 CTL101 Back View T E C H N I C A L S U P P O R T : (800) 882-7117 (714) 921-4100 MADE IN U.S.A www.inlineinc.com IR SENSOR INPUT 9 0-2 60 VA C; 0. 05 A; 47- 63Hz CONTACT CLOSURE IR OUT + – EXT INT SENSOR MODE FUSE: 0.
12 CTL101 Connectors and Controls FRONT PANEL INDICATORS The Remote and Power LED’s, and the IR receiver sensor are located on the front panel of the CTL101 (see the diagram on the following page). The Power LED will illuminate as soon as power is applied to the unit (the CTL101 has no ON/OFF switch). The Remote LED will illuminate whenever the interface receives an infrared signal from any IR remote control.
13 DIPSWITCH SETTINGS On the bottom of the unit are two sets of dipswitches. Dipswitch Bank #1 is used to configure the serial ports to operate as an RS-232, or RS-422 / RS-485 physical interface. Dipswitch Bank #2 is used to isolate the contact closure ports and to configure the CTL101 to the default baud rate (9600).
14 Dipswitch Bank #2: Dipswitches 1, 2, 3, 4: 1 & 2 in "1" position 3 & 4 in "0" position Contact Closure Port +5V Enable / Disable: Enabled (CTL101 provides power) Contact Closure Port Ground Enabled / Disabled: Enabled (CTL101 provides power) Baud Rate Override (Cycle power off / on to activate new setting): Normal Dipswitch Dipswitch Bank #1 Function 1, 2 & 3 Input Port Serial Mode 4, 5 & 6 Output Port Serial Mode Dipswitch 1 2 3 4 Dipswitch Bank #2 Function Contact Closure Port +5V Enable / Di
15 Serial Port Set-Up Preprogrammed command functions can be sent via the RS-232 / RS-422 / RS-485 serial output port. The CTL101 accepts serial commands from a control system, computer serial port or any other device capable of sending out serial ASCII commands at compatible baud rates, and relays the commands to the video equipment via the output port. RS-232, RS-422 & RS-485 FORMATS RS-232, RS-422 and RS-485 formats are physical interface standards for serial communication.
16 TERMINAL EMULATION PARAMETERS* In order for the workstation to communicate with the CTL101, the terminal emulation program parameters must be set as follows: Enabled: VT100 Terminal Emulation Echo Typed Characters Locally (sending) Wrap Lines that Exceed the Terminal Width (receiving) Disabled: XON / XOFF Control Hardware Flow Control Echo Received Characters * Software comes standard with the Windows™ Package. By default, the CTL101 is set up to accommodate most common terminal emulation programs.
17 The next series of menus will look like this: Switch Codes - enter selection. 1. Clear All switch codes. 2. Switch closure code. (ASCII format) 3. Switch open code. (ASCII format) 4. Switch closure code. (HEX format) 5. Switch open code. (HEX format) 6. Exit. Select 2, 3, 4, or 5. Enter Switch # (1 - 16). Select the switch #. **New: Enter selection. 1. Enter code. 2. Delete code. 3. Display current. 4. Exit. Select "1".
18 INFRARED CODES If the application involves infrared codes, type "2"in the main menu followed by ENTER. The next series of menus will look like this: IR 1. 2. 3. 4. 5. Select 2, or 3. Codes - enter selection. Clear All codes in user programmable group. Set/Change/Clear/Display a code. (ASCII format) Set/Change/Clear/Display a code. (HEX format) Select current code group. Exit. **Press remote button. **Press again - Verify. **New: Enter selection. 1. Enter code. 2. Delete code. 3. Display current. 4.
19 2 & 3. Set / Change / Clear / Display a Code - will prompt users to push an IR remote control button to be associated with the operations. Another prompt will be displayed to verify the selection. If the IR signal is acceptable, the unit will indicate if it is a "New" or "Existing" command code. A new feature includes Hexadecimal code entry (HEX format). HEX format codes must be entered in pairs (even number of entries).
20 REPROGRAMMING OR USING A DIFFERENT IR REMOTE CONTROL The CTL120 IR Remote is pre-programmed at the factory and will readily support most applications. However, If operators wish to use their own remote, or if the CTL120 commands interfere / are incompatible with components in the system, the existing command codes may have to be changed. Recommended manufacturer’s command codes include Sony (default), JVC, Panasonic, Pioneer and RCA/Proscan.
21 2. Flow Control - The Input Serial Port (host computer) can receive XON / XOFF flow control from the CTL101. This is beneficial when the host computer is controlling the video equipment simultaneously with a contact closure and / or IR signal. If a contact change or an IR signal is sensed, the CTL101 will send an XOFF command to the computer (once a delimiter is received from the computer going to the equipment, or a one second timeout).
22 1. Don’t Wait For Response - allows the CTL101 to deliver a command without receiving an end delimiter from the controlled equipment. In most instances this mode is used because it decreases the CTL101 response time (it does not have to wait for a response before the next command [button push] can be issued). All commands sent to INLINE units must contain a leading code, the command code, and an ending code.
23 SELF-TEST If SELF-TEST is selected, the next series of menus will look like this. Test Results - Rev. 1.2 SRAM...........(PASS) Flash..........(PASS) RHost Serial....(PASS) Inline Serial..(PASS) Press button on remote. **Press again - Verify. IR Signal......(PASS) Switch 1 to 8..(PASS) Switch 9 to 16.(PASS) Remove test cable from switches (10 second timeout). Switch 1 to 8..(PASS) Switch 9 to 16.
24 Specifications CTL101 Control Interface Control Ports: IR Remote Sensor Port IR Emitter Port Contact Closure Port Contact Closure Signals Contact Closure Power Serial Input Port Serial Output Port Serial Interface Formats Default Serial Protocol Flow Control Serial Port Baud Rates General Command Capacity IR Sensor Remote Sensor Power Supply Product Weight Shipping Weight Dimensions Regulatory Compliance 4-Pin Captive Screw Terminal 2-Pin Captive Screw Terminal (2) 10-Pin Captive Screw Terminals (16) C
25 Optional Accessories IR Accessories CTL120-1: IR Remote Control CTL120-2: IR Remote Control with Overlay for IN1402 / IN1403 / IN1404 Video Scalers, IN3600 Series Switchers and the IN31608 Matrix Switcher CTL130: IR Emitter CTL131DB: Remote IR Sensor - Double Size A/V Connector Module - Black CTL131DW: Remote IR Sensor - Double Size A/V Connector Module - White Mounting Hardware IN9080: Rack Shelf - For mounting the CTL101 in a standard 19" equipment rack IN9088B: Half-Rack Blank Plate - Fills space whe
26 Problem: screen. Solution: Command code strings can only consist of (up to) 120 characters. When the message appears, back up one command and terminate the string by using an asterisk (*). Problem: Infrared remote commands are responding very slowly. Solution: Problem: While entering a command code, a "Code Area is Full" message appears on the Unless a string of commands is involved, avoid setting the DELIMITER PAUSE. There is no response from serial commands.
CONNECTORS & CONTROLS CTL120-2 REMOTE CONTROL IN3808 / IN20804 / IN21608 / IN31208 / IN31608 Matrix Switchers MATRIX 1st BUTTON TO PRESS Matrix Button Press this button first to set the CTL120 to control an INLINE matrix switcher Numeric Buttons Select the desired input or memory POWER S VIDEO SCALER SWITCHER MATRIX AUDIO 1 2 3 4 5 6 7 8 9 ENTER 0 PIP Input Button Selects inputs in Direct Switching mode. Press this button first, followed by two numeric buttons and ENTER.
CONNECTORS & CONTROLS CTL120-2 REMOTE CONTROL IN1402 / IN1403 / IN1404 / IN1408 Video Scalers VIDEO SCALER 1st BUTTON TO PRESS Video Scaler Button Press this button first to set the CTL120 to control IN1400 Series video scalers Numeric Buttons Select desired input POWER S VIDEO SCALER Freeze Button Enable / Disable digital still frame SWITCHER MATRIX AUDIO 1 2 3 4 5 6 7 8 9 ENTER 0 PIP Menu Button Activates or removes on–screen menus ENT INPUT RECALL Enter Button Press to make a men
CONNECTORS & CONTROLS CTL120-2 REMOTE CONTROL IN3600 Series Switchers SWITCHER 1st BUTTON TO PRESS Switcher Button Press this button first to set the CTL120 to control IN3600 Series switchers POWER S VIDEO SCALER SWITCHER MATRIX AUDIO 1 2 3 4 5 6 7 8 Numeric Buttons Press to select the desired input 9 ENTER 0 PIP ENT INPUT RECALL FREEZE MENU MENU OK ENTER CH VOL + – BLANK + – MUTE CTL120-2 COMMAND EXAMPLES FOR IN3600 SERIES SWITCHERS SWITCHER IMPORTANT: You must press the SW
30 Warranty ♦ INLINE warrants the equipment it manufactures to be free from defects in materials and workmanship. ♦ If equipment fails because of such defects and INLINE is notified within three (3) years from the date of shipment, INLINE will, at its option, repair or replace the equipment at its plant, provided that the equipment has not been subjected to mechanical, electrical, or other abuse or modifications.