User`s manual
Cable Cubby
®
Products • Maintenance and Modications
Maintenance and Modifications, cont’d
3-8
Cable Cubby
®
Products • Maintenance and Modications
3-9
• Cable Cubby 600 and 800 US/Domestic models —
You probably do need replacement shelf brackets
when you add a US/Domestic power module to
a US/Domestic Cable Cubby, because the power
module takes up two spaces in a cubby that, in its
standard conguration, is equipped with three-space
(Cable Cubby 600) or four-space (Cable Cubby 800)
shelves.
Figure 3-5 shows typical congurations before and after
you add a second US/Domestic power module to a
US/domestic Cable Cubby 600 and suggests rack shelf
congurations to replace the lost shelf space.
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
100-240V/ 5AMAX
or
Before
Three AAP
Space Shelf
Three AAP
Space Shelf
Four AAP
Space Shelf
Two AAP
Space Shelf
Two AAP
Space Shelf
After
Figure 3-5 — Cable Cubby 600 with second power
module
Figure 3-6 shows typical congurations before and after
you add a second US/Domestic power module to a
US/domestic Cable Cubby 800 and suggests rack shelf
congurations to replace the lost shelf space.
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
100-240V/ 5AMAX
or
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
100-240V/ 5AMAX
UNSWITCHED
100-240V/ 5AMAX
Before
After
VIDEO AUDIO
L R
VIDEO AUDIO
L R
Three AAP
Space Shelf
Four AAP
Space Shelf
Two AAP
Space Shelf
Three AAP
Space Shelf
Four AAP
Space Shelf
Four AAP
Space Shelf
Figure 3-6 — Cable Cubby 800 with second power
module
2
If the Phillips head screws on the front and rear of the
cubby are blocked by the table, remove the cubby from the
table. See "Removing and Replacing the Cable Cubby",
steps 1 through 4, earlier in this chapter.
3
Before you add an additional power module, you must
make room for the Cable Cubby by eliminating two or
three AAP spaces and the AAP shelf brackets that support
them. Remove the Phillips head screws on the front and
rear of the Cable Cubby and gently push the assembly(ies)
out through the bottom of the cubby.