User`s manual
Cable Cubby
®
Products • Maintenance and Modications
Maintenance and Modifications
Cable Cubby
®
Products • Maintenance and Modications
3-33-2
The Cable Cubby can be modied after installation to change
cables, to replace an AAP, or to add a second power module.
These modications may require removing the cubby from the
table.
Removing and Replacing the Cable Cubby
You may need to remove the cubby from the table in which
it is mounted to replace cables or AAPs, to adjust the height
of the AAP assemblies, or to install a second power module.
Figure 3-1 shows removal of the Cable Cubby 300, 600, or 800
from the table and removal of the AAP shelf assembly and
power module.
N
The Cable Cubby 200 is screwed to the top surface of the
table. Its shelves are fixed in position and not removable.
Remove and replace the Cable Cubby for maintenance as
follows:
W
Ensure that AC power is disconnected before
servicing the Cable Cubby.
1
. Cable Cubby 300, 600, and 800 — Loosen
the locking thumbscrews on the screw
clamps to unlock the clamp (gure 3-1).
2. Cable Cubby 300, 600, and 800 — Loosen
the screw clamps.
3. Cable Cubby 300, 600, and 800 — Remove the screw
clamps on both sides of the enclosure.
Extron
Cable Cubby 800
Pins
Phillips Head Screw
(Secures AAP Shelf Assembly
and Power Module.)
Screw Clamp
Figure 3-1 — Removing the cubby and its shelves