User Guide User guide
Command ASCII (Telnet)
(host to processor)
URL Encoded (Web)
(host to processor)
Response
(processor to host)
Additional description
Configure redirect mode
EX12%
*
X14#
*
X14$
*
X13!
CD
}
WX12%%2AX14#%2AX14$
%2A
X13!CD|
Cpn
X12%•
Ccd
X14#
,
X14$
,
X13!]
Terminate redirect mode
EX12%
*0CD
}
WX12%%2A0CD|
Cpn
X12%•
Ccd00000,00000,
00000L
]
Read redirect mode
EX12%
CD
}
WX12%CD|
X14#
,
X14$
,
X13!]
Ethernet data port
Set current conn port time-out
E0
*
X14@
TC
}
W0%2AX14@TC|
Pti0*
X14@]
Read current conn port time-
out
E0
TC
}
W0TC|
X14@]
Set global IP port time-out
E1
*
X14@
TC
}
W1%2AX14@TC|
Pti1*
X14@]
Read global IP port time-out
E
1TC
}
W1TC|
X14@]
Directories
Change/create directory
Epath/directory/
CJ
}
Wpath/directory/%2FCJ|
Dir
•
path/directory/
]
Back to root directory
E/
CJ
}
W%2FCJ|
Dir
•/]
Up one directory
E~
CJ
}
W%2E%2ECJ|
Dir
•
path/directory/
]
View current directory
E
CJ
}
WCJ|
path/directory/
]
directory = A text string drawn from the alphabet (A-Z), digits (0-9), minus sign/hyphen (-). No blank or space characters are permitted as part of the name.
No distinction is made between upper and lower case. The first character must be an alpha character.
NOTE: A directory does not truly exist until a le has been copied into that path.
Unlike various PC operating systems, a le and directory on the Extron product are allowed to have the same name.
The current directory is a per-connection setting. It begins at the root for each IP session.
NOTE: X12% = specic serial port number (01-03), 01 = COM1 (rear panel, bottom port), 02 = COM2 (front panel cong port), 03 = COM3 (rear panel, top
port)
X13! = Parameter (#L or #D) to set either the Length of message to receive or the Delimiter value. # = byte count (for L) or # = a single ASCII character
expressed in decimal form (for D). The parameter is case sensitive. Byte count is 0 to 32767 (default = 0.)
X14@ = IP connection time-out period specied in 10-second steps , 1 - 65000 (default = 30 = 300 seconds). If no data is received in the specied period,
the connection closes.
X14# = Redirection status: 0 = no redirection, 1 - 3 = redirect serial communication to COM1, COM2,or COM3
X14$ = Time-out period in tens of milliseconds for serial data pass-through mode, range = 1 - 32767 (default = 10 = 100 ms)
Annotator • SIS Communication and Control 59