User Guide User guide

Command ASCII (Telnet)
(host to processor)
URL Encoded (Web)
(host to processor)
Response
(processor to host)
Additional
description
Set verbose mode
EX12#
CV
}
W
X12#
CV
|
Vrb
X12#]
Read verbose mode
E
CV
}
WCV
| X12#]
Event control
Start events
E
1AE
}
W1AE
|
Ego
]
Stop events
E
0AE
}
W0AE
|
Est
]
Read number of events running
E
AE
}
WAE
|
#####
]
Returns a five-digit
number.
(tagged response in verbose mode 2/3)
Emm #####
]
Verbose mode
Bidirectional serial data port
Set parameters
EX12%
*
X13%
,
X13^
,
X13&
,
X13*
CP
}
W
X12%
%2A
X13%
%2C
X13^
%2C
X13&
%2C
X13*
CP
|
Cpn
X12%•
Ccp
X13%
,
X13^
,
X13&
,
X13*]
Read parameters
EX12%
CP
}
W
X12%
CP
|
X13%
,
X13^
,
X13&
,
X13*]
Set mode
EX12%
*
X13(
CY
}
W
X12%
%2A
X13(
CY
|
Cpn
X12%•
Cty
X13(]
Read mode
EX12%
CY
}
W
X12%
CY
| X13(]
Congure ow control
EX12%
*
X14)
,
X14!
CF
}
W
X12%
%2A
X14)
%2C
X14!
CF
|
Cpn
X12%•
Cfl
X14)
,
X14!]
Read ow control
EX12%
CF
}
W
X12%
CF
|
X14)
,
X14!]
Configure receive time-out
EX12%
*
X12&
*
X13)
*
X13#
*
X13!
CE
}
W
X12%
%2A
X12&
%2A
X13)
%2A
X13#
%2A
X13!
CE
|
Cpn
X12%•
Cce
X12&
,
X13)
,
X13#
,
X13!]
Read receive time-out
EX12%
CE
}
W
X12%
CE
|
X12&
,
X13)
,
X13#
,
X13!]
NOTE:
X12#
= Verbose mode: 0 = clear/none,1= verbose mode, 2 = tagged, 3 = verbose and tagged
X12$
= RAM status, 0 = dirty (needs saving), 1 = saved
X12%
= Specic serial port number (01-03), 01 = COM1 (rear panel, bottom port), 02 = COM2 (front panel cong port), 03 = COM3 (rear panel, top port)
X12& = Time in tens of milliseconds to wait until the rst response character is received via a serial port before terminating the current receive operation.
(Default = 10 = 100 ms, max. = 32767.)
X13) = Time in tens of milliseconds to wait between characters being received via a serial port before terminating the current command or receive
operation. (Default = 2 = 20 ms, max. = 32767.)
X13! = Parameter (#L or #D) to set either the Length of message to receive or the Delimiter value. # = byte count (for L) or # = a single ASCII character
expressed in decimal form (for D). The parameter is case sensitive. Byte count is 0 to 32767 (default = 0).
X13# = Priority status for receiving time-outs: 0 = use send data string command parameters (default), 1 = use congure receive time-out
command parameters
X13% = Baud rate: 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600 (default), 14400, 19200, 28800, 38400, 57600, or 115200
X13^ = Parity (only the rst letter is needed), O = odd, E = even, N = none (default), M = mark, S = space
X13& = Data bits: 7, 8 (default = 8)
X13* = Stop bits: 1, 2 (default = 1)
X13( = Serial port type, 0 = RS-232, 1 = RS-422
X14) = Flow control (only the rst letter is needed), H = hardware, S = software, N = none
X14! = Data pacing (time between bytes) in milliseconds (0000 - 1000). (default = 0000 = 0 ms).
Annotator • SIS Communication and Control 58