User Guide User guide
Command ASCII command
(host to processor)
Response
(processor to host)
Additional description
Scan converter horizontal size
Specific value
ESX1&HSIZ} HsizSX1&]
Set horizontal size to
X1&
.
Increase size
ES+HSIZ} HsizSX1&]
Widen image.
Decrease size
ES-HSIZ} HsizSX1&]
Make image narrower.
View
ESHSIZ} X1&]
Horizontal size is
X1&
.
Scan converter vertical size
Specific value
ESX1&VSIZ} VsizSX1&]
Set vertical size to
X1&
.
Increase size
ES+VSIZ} VsizSX1&]
Make image taller.
Decrease size
ES-VSIZ} VsizSX1&]
Make image shorter.
View
ESVSIZ} X1&]
Vertical size is
X1&
.
Scan converter horizontal filter
Set detail level
ESX7&HDET} HdetSX7&]
Set H lter level to
X7&
.
Increment up
ES+HDET} HdetSX7&]
Increase H lter level.
Increment down
ES-HDET} HdetSX7&]
Decrease H lter level.
View detail value
ESHDET} X7&]
H lter level is
X7&
.
Scan converter flicker filter
Set icker lter level
ES
X7&
VDET} VdetSX7&]
Specify the icker lter level to X7&.
Increment up
ES+VDET} VdetSX7&]
Increase the icker lter level.
Increment down
ES-VDET} VdetSX7&]
Decrease the icker lter level.
View icker lter level
ESVDET}
X7&]
View the icker lter level.
Scan converter encoder filter
Set encoder filter level
ES
X7&
VENC}
VencS
X7&]
Set video encoder filter level to X7&
.
View
EVENC}
X7&]
View the encoder filter level.
Presets
User presets
Recall presets
1*
X2%. 1RprX2%
]
Recalls user preset
X2%
for selected
input.
Save presets
1*
X2%, 1SprX2%
]
Saves user preset
X2%
for selected
input.
Input presets
Recall presets
2*
X2^
. 2RprX2^
]
Recalls input preset
X2^
.
Save presets
2*
X2^
, 2SprX2^
]
Saves input parameters to preset
X2^
.
Auto Memory
Enable
E
1AMEM}
Amem1
]
Set auto memory on. Previous
settings for incoming signal are auto
recalled.
Disable
E0AMEM} Amem0]
Set auto memory off. Default settings
are always used unless input preset is
recalled manually.
View setting
EAMEM} X1)]
View auto memory status.
NOTE: X1) = off/disable (0), on/enable (1)
X1& = H and V size, 0 to 200% of the output area in single pixel increments
X2% = Memory presets 1 to 16
X2^ = Input presets 1 to 128
X7&
= Filter level, 0 to 3
Annotator • SIS Communication and Control 48