User Guide User guide
Processor-Initiated Messages
When a local event such as a front panel operation occurs, the processor responds by 
sending a message to the host. The processor-initiated messages are listed below.
With an RS-232/422 connection (upon power up):
(c) Copyright 2009, Extron Electronics Annotator, Vx.xx, 60-968-14] 
With an Internet connection:
(c) Copyright 2009, Extron Electronics Annotator, Vx.xx, 60-968-14]
Ddd, DD MMM YYYY HH:MM:SS (day, date time. for example. Tue, 14 Apr 2009 
14:43:17)
The processor initiates the copyright message when powered on or when connection via 
Internet protocol (IP) is established. Vx.xx is the firmware version number.
]Password: 
The processor initiates the password message immediately after the copyright message 
when the controlling system is connected using TCP/IP or Telnet and the processor is 
password protected. The processor requires an administrator or user level password before 
performing the commands entered.
NOTE:  Password prompt is re-displayed if an incorrect password is entered.
]Login Administrator] and ]Login User] 
The processor initiates the login message when a correct administrator or user password 
has been entered. If the user and administrator passwords are the same, the processor 
defaults to administrator privileges.
Reconfig]
The processor sends the Reconfig message whenever a new resolution is applied.
NOTE:  Response is seen via RS-232 connection only.
Exen]
The processor initiates the Exe message when executive mode is toggled on or off from 
the front panel. “n” is the executive mode status: 1 = on, 0 = off.
Processor Error Responses
When the Annotator receives an SIS command and determines that it is valid, it performs 
the command and sends a response to the host device. If the processor is unable to 
perform the command because the command is invalid or contains invalid parameters, the 
processor returns an error response to the host. The error response codes are:
  E01 — Invalid input channel number (out of range) 
  E10 — Invalid command 
  E11 — Invalid preset number 
  E12 — Invalid output number/port number 
  E13 — Invalid parameter (out of range) 
  E14 — Command not available for this conguration 
  E17 — Invalid command for this signal type 
  E22 — Busy 
  E24 — Privilege violation 
  E25 — Device not present  
  E26 — Maximum number of connections exceeded 
  E27 — Invalid event number 
  E28 — Bad lename/le not found