Setup Guide CrossPoint 450 Plus Series MAV Plus Series Large Scale Matrix Switchers Extron USA - West Headquarters +800.633.9876 Inside USA / Canada Only +1.714.491.1500 +1.714.491.1517 FAX Extron USA - East Extron Europe Extron Asia Extron Japan Extron China Extron Middle East +800.633.9876 +800.3987.6673 +800.7339.8766 +81.3.3511.7655 +81.3.3511.7656 FAX +400.883.1568 +971.4.2991800 +971.4.2991880 FAX +1.919.863.1794 +1.919.863.1797 FAX +31.33.453.4040 +31.33.453.4050 FAX +65.6383.
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
安全须知 • 中文 警告 这个符号提示用户该设备用户手册中 有重要的操作和维护说明。 电源 • 该 设 备 只 能 使 用 产 品 上 标 明 的 电 源 。 设 备 必须使用有地线的供电系统供电。 第三条线 (地线)是安全设施,不能不用或跳过。 这个符号警告用户该设备机壳内有暴 拔掉电源 • 为安全地从设备拔掉电源,请拔掉所有设备后 或桌面电源的电源线,或任何接到市电系统的电源线。 露的危险电压,有触电危险。 电源线保护 • 妥善布线, 避免被踩踏,或重物挤压。 注意 阅读说明书 • 用 户 使 用 该 设 备 前 必 须 阅 读 并 理 解所有安全和使用说明。 保存说明书 • 用户应保存安全说明书以备将来使 用。 遵守警告 • 用户应遵守产品和用户指南上的所有安 全和操作说明。 维护 • 所有维修必须由认证的维修人员进行。 设备内部 没有用户可以更换的零件。为避免出现触电危险不要自 己试图打开设备盖子维修该设备。 通风孔 • 有些设备机壳上有通风槽或孔,它们是用来防止 机内敏感元件过热。 不要用任何东西挡住通风孔。 锂电池 • 不正确的更换电池会有爆炸的危险。 必须使用 与厂家推荐的相同
Table of Contents Chapter One • Introduction ..................................................... 1-1 About this Manual ..................................................................... 1-2 About the Matrix Switchers ................................................... 1-2 Chapter Two • Installation ....................................................... 2-1 Rear Panel Installation Features ............................................
Table of Contents, cont’d CrossPoint 450 Plus / MAV Plus Matrix Switchers 1 Chapter One Introduction About this Manual About the Matrix Switchers ii CrossPoint / MAV Matrix Switchers • Table of Contents Refer also to the CrossPoint 450 Plus / MAV Plus User’s Manual at www.extron.com.
Introduction N For more information on any subject in this guide, refer to TCP/IP Network the CrossPoint 450 Plus / MAV Plus User’s Manual, available on the Extron DVD or at www.extron.com. Control System BME 0 (red) 12 9 17 18 22 23 24 25 26 27 28 • • 1-2 CrossPoint 450 Plus Wideband video — Routes a single video plane (red [R], green [G], or blue [B]). CrossPoint 450 Plus Sync — Routes a single sync plane (horizontal [H], vertical [V], or composite sync [S]).
Introduction, cont’d CrossPoint 450 Plus / MAV Plus Matrix Switchers 2 Chapter Two Installation Rear Panel Installation Features Front Panel Configuration Port 1-4 CrossPoint / MAV Matrix Switchers • Introduction Refer also to the CrossPoint 450 Plus / MAV Plus User’s Manual at www.extron.com.
Installation 3 * N Extron recommends locking redundant front panel 1 controllers (if included in your system). See page 3-4.
Installation, cont’d e Audio inputs (audio BMEs) — Connect stereo or mono audio sources to the 5-pole or 3-pole captive screw connectors. Tip Ring Sleeve (s) Tip Ring Unbalanced Stereo Input R Tip Sleeve L Tip Sleeve Balanced Stereo Input Do not tin the wires! Computer or control system connection — Wire the interface cable as a crossover cable.
Installation, cont’d Power connection k Power — Plug the switcher into a grounded AC source. Front Panel Configuration Port I/O CONTROL VIEW ESC I/O CONFIG VIDEO AUDIO POWER SUPPLY PRIMARY REDUNDANT CROSSPOINT 450 PLUS SERIES ULTRA WIDEBAND MATRIX SWITCHER 12 l Configuration port — If desired, connect a control system or computer to the front panel Configuration (RS-232) port. Use an optional 9-pin D to 2.5 mm mini jack TRS RS-232 cable, part #70-335-01.
Front Panel Operation 1 2 3 4 5 5. 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 I N P U T S Saving or Recalling a Preset 1. 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 2 3 4 5 I/O CONTROL ENTER 1 PRESET VIEW ESC VIDEO O U T P U T S 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 I/O CONFIG Save a preset — Press and hold the Preset button until it flashes.
Front Panel Operation, cont’d Setting the Front Panel Locks (Executive Modes) The matrix switcher has three levels of front panel security lock that limit the operation of the switcher from the front panel. The three levels are: • Lock mode 0 — The front panel is completely unlocked. • Lock mode 1 — All changes are locked from the front panel (except for setting Lock mode 2). Some functions can be viewed. • Lock mode 2 — Basic functions are unlocked. Advanced features are locked and can be viewed only.
Front Panel Operation, cont’d Viewing Ties (and Muting Outputs) 1. Press the View button. Output buttons light for outputs that have no ties established. N If an output button blinks, that output is muted. 2. Press an input button. The buttons for all tied outputs light (amber for video and audio, green for video only, and red for audio only). 3. Press an output button. The buttons for the tied input and all tied outputs light. 4.
Remote Control Selected SIS Commands The switchers have Simple Instruction Set (SIS ) commands that you can use for operation and configuration. You can run these commands from a PC connected to either of the switcher’s serial ports or the Ethernet port. See g (page 2-4), h (page 2-5), and l (page 2-6), for connection information.
ASCII command (host to switcher) Response (switcher to host) Additional description Refer also to the CrossPoint 450 Plus / MAV Plus User’s Manual at www.extron.com. CrossPoint / MAV Matrix Switchers • Remote Control Create ties • Commands can be entered back-to-back in a string, with no spaces. For example: 1*1!02*02&003*003%4*24$. • The matrix switchers support 1-, 2-, and 3-digit numeric entries (1*1!, 02*02&, or 003*003%).
ASCII command Response (host to switcher) (switcher to host) Set the audio volume to a specific value Example: X@*X%V OutX@•VolX%] 1*50v Out01•Vol50] Increment volume X@+V OutX@•VolX%] Additional description Audio output volume Refer also to the CrossPoint 450 Plus / MAV Plus User’s Manual at www.extron.com.
ASCII command Response Additional description (host to switcher) (switcher to host) I VX*XX(•AX*XX(TX1@UX1#] Information requests Refer also to the CrossPoint 450 Plus / MAV Plus User’s Manual at www.extron.com. CrossPoint / MAV Matrix Switchers • Remote Control Information request VX*XX( = video size, AX*XX( = audio size, TX1@ = BME type, UX1# = # of BMEs in system.
Remote Control, cont’d Installing and Starting the Control Program 4. Another way to operate the switcher is via the Windows -based Matrix Switchers Control Program. This program is contained on the Extron Software Products DVD (included with the switcher). Run this program on a PC connected to either of the switcher’s serial ports or the Ethernet port. See g (page 2-4), h (page 2-5), and l (page 2-6), for connection information.
Remote Control, cont’d 3. If you selected IP [LAN] in step 2, the IP Connection window appears. Accessing the HTML Pages Another way to operate the switcher is via its factory-installed HTML pages, which are always available and cannot be erased or overwritten. The switcher’s HTML pages are accessible through its LAN port, connected via a LAN or WAN, using a web browser such as Microsoft Internet Explorer. See h on page 2-5, for connection information. Configuring for Network Communication a.
Remote Control, cont’d After receiving the arp -s command, the controller changes to the new address and starts responding to the ping requests, as described in step 5. Loading the start-up page N If your Ethernet connection to the matrix switcher is unstable, try turning off the proxy server in your Web browser. In Microsoft Internet Explorer, click Tools > Internet Options > Connections > LAN Settings, uncheck the Use a proxy server... box, and then click OK.