Command and Response Table for SIS Commands (continued)
Command SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Names
NOTES:
• The HTML language reserves certain characters for specific functions (see Special Characters on page 35).
• Do not use leading spaces in preset names.
• If a preset is unassigned, the
X1)
displays [unassigned].
• If a global preset is saved, but not yet named, the default name is Preset•
X&
.
• If a room preset is saved, but not yet named, the default name is Rm
X*
•Prst
X(
.
Write global preset name
EX&
,
X(
NG
}
Nmg
X&
,
X(]
Example:
E
1,Security 1NG
}
Nmg001,Security 1
]
Name global preset 1 “Security 1.”
Read global preset name
EX&
NG
} X(]
Example:
E
2NG
}
Security 2
]
Global preset 2 is named “Security 2.”
Write room preset name
EX*
*
X1)
,
X(
NP
}
Nmp
X*
*
X1)
,
X(]
Example:
E
1*3,Podium_DVDNP
}
Nmp01*3,Podium_DVD
]
Name room1, preset 3 “Podium_DVD.”
Read room preset name
EX*
*
X1)
NP
} X(]
Write input name
EX1@
,
X(
NI
}
Nmi
X1@
,
X(]
Example:
E
1,Podium camNI
}
Nmi001,Podium cam
]
Name input 1 “Podium cam.”
Read input name
EX1@
NI
} X(]
Write output name
EX@
,
X(
NO
}
Nmo
X@
,
X(]
Example:
E
1,Main PJ1NO
}
Nmo001,Main PJ1
]
Name output 1 “Main PJ1.”
Read output name
EX@
NO
} X(]
Resets
Reset global presets and
names
E
ZG
}
Zpg
]
Clear all global presets and their names.
Reset one global preset
EX&
ZG
}
Zpg
X&]
Clear global preset
X&
.
Reset all mutes
E
ZZ
}
Zpz
]
Unmute all outputs.
Reset room map
E
ZR
}
Zpr
]
Clear all room definitions.
Reset individual room
EX*
ZR
}
Zpr
X*]
Delete room
X*
.
Reset all room presets
E
ZP
}
Zpp
]
Clear all room presets and names.
Reset individual room preset
EX*
*
X1)
ZP
}
Zpp
X*
*
X1)]
Clear an individual room preset and name.
Reset whole switcher
E
ZXXX
}
Zpx
]
Clear all ties and presets.
Absolute reset
E
ZQQQ
}
Zpq
]
Similar to Reset whole switcher, plus clear
the IP address to 192.168.254.254 and subnet
mask to 255.255.000.000.
Reset all device settings
E
ZY
}
Zpy
]
NOTE:
X@
= Output number 01 – (maximum number of outputs for your configuration)
X& = Global preset # 001 – 064
X* = Room # (for room presets) 01 – 10 (each can have up to 10 presets (X1)s) assigned)
X( = Name 11 characters maximum for room names
12 characters maximum for all other names
X1) = Room preset # 00 – 10 (0 = current configuration for room)
X1@ = Input number (for other than tie) 01 – (maximum number of inputs for your configuration)
FOX Matrix 320x and FOX Matrix 14400 • Programming Guide
29