- Extron Electronics Multi-Graphic Processor User's Manual
Table Of Contents
- Chapter One
- Introduction
- Chapter Two
- Installation
- Chapter Three
- Operation
- Front Panel Features
- Power-up and Default Cycle
- Window Select Buttons
- Input Selection
- Menus, Configuration, and Adjustments
- Picture Controls
- Auto Memories
- Memory Presets
- Additional Features
- Chapter Four
- Software Configuration and Control
- Chapter Five
- HTML Configuration and Control
- Accessing the Web Pages
- Viewing System Status
- Using the Configuration Page
- Using the File Management Page
- Using the Control Page
- Using the Background Page
- Chapter Six
- Special Applications
- Appendix A
- Specifications, Part Numbers, and Accessories
- Appendix B
- Firmware Update Guide

SIS
™
Programming and Control, cont’d
MGP 464 • Software Conguration and Control
4-16
PRELIMINARY
Command/response table for SIS commands (continued)
Command
ASCII (Telnet)
(host to processor)
Response
(processor to host)
Additional description
Input presets
Recall input preset
3 *
X50@
*
X51$
. Rpr 3 *
X51$
]
Recall input preset
X51$
to window
X50@
.
X50@
= 0 through 4; 0 = all windows.
X51$
= 1 through 128.
Save input preset
3 *
X50@
*
X51$
, Spr 3 *
X51$
]
Save the input settings for window
X50@
to input
preset
X51$
.
Input naming
Write input name
E
X50)
,
X50^
NI
}
Nmi
X50)
,
X50^
]
Create a text label containing name
X50^
for input
X50)
.
X50)
= 1 through 19.
X50^
= up to 16 characters. For
X50^
, use:
Symbols: : / – _ + “ (space)
Numerals: 0 through 9
Letters: Lowercase a through z and
uppercase A through Z
Read input name
E
X50)
NI
} X50^
]
View contents of the name label for input
X50)
.
Window preset naming
N
Window preset names cannot be viewed on the LCD screen. They can be viewed on the MGP 464 Web page, the Windows-based control software, or via SIS commands.
Write preset name
E
X51#
,
X50^
NP
}
Nmp
X51#
,
X50^
]
Give the window preset
X51#
the name
X50^
.
X51#
= 1 through 128.
Read preset name
E
X51#
NP
} X50^
]
View window preset name
X50^
.
Vertical start
Specific value
X50)
*
X51@
( Vst
X50)
*
X51@
]
Set the vertical position of the first active pixel for
input
X50)
to
X51@
.
X51@
= 0 through 255; default = 128.
Increment vertical start value
X50)
+ ( Vst
X50)
*
X51@
]
Increase vertical start location value for input
X50)
.
Decrement vertical start value
X50)
– ( Vst
X50)
*
X51@
]
Decrease vertical start location value for input
X50)
.
View vertical start setting
X50)
(
X51@
]
View the vertical start location of the rst active
pixel in the active window.