User Manual

28 Installing the Extricom WLAN System
The maxim
u
m length o
f the
primary to secondary
switch interconnect is computed
according to the following tables: (all distances in meters)
Interconnect Using CAT-5e/6 100/1000Mbps Cable:
Distance Between
Secondary
Switch and Its Farthest AP
Max.
Switch
Interconnect
D
istanc
e
(Copper Interconnect Cable)
50
150
100
100
150
50
175
25
190
10
Interconnect Using Fiber Media Cable:
Distance Between
Secondary
Switch and Its Farthest AP
Max.
Switch
Interconnect
D
istance
(Fiber Interconnect Cable)
50
500
100
300
150
150
1
75
75
Note: Beyond 100 m, copper-based cables require a range extender.
Mounting the Access Points (Optional)
Extricom EXRP-20E/40E/40En APs can be mounted on the wall or ceiling. For this purpose, a
separate mounting bracket is provided for ease of installation. The bracket has two holes for
mounting to the wall, and one hole for a screw that mounts the AP to the bracket.
Extricom EXRP-20/40/30n APs can be mounted on the wall or ceiling. To mount the APs, you will
need two stainless steel pan head 8x1-1/4" self-tapping Phillips screws.
To mount the EXRP-20/40/30n Access Points:
1. Place the installation template (refer to Error! Reference source not found. in this Guide) on
the wall where you want to mount the AP.
2. Mark the "Point for Drilling" locations on the wall.
3. Screw the two stainless steel pan head 8x1-1/4" self-tapping Phillips screws into the wall
leaving enough of the screws protruding to enable you to hook the AP over the screw.
4. Align the holes on the back of the AP with the screws and slip the AP into place.