Specifications
4
WWW.EXTREMENETWORKS.COM
Scaling and Performance
• MAC Addresses: 290K
• IPv4 LPM Entries: 128K max w/ALPM
• IPv4 Hosts:
• with min LPM IPv4 entries: 180K
• with max LPM IPv4 entries: 164K
• IPv6 LPM (/64) Entries: 64K max w/ALPM
• IPv6 Hosts: 56K max
• IP Multicast Groups - 8K
• IP Multicast (s,v,g) entries - 136K max
• Flexible Universal Forwarding Tables (UFT)
• 4092 user-created VLAN/VMANs
• 9216 Byte Max Packet Size (Jumbo Frame)
• 8 queues per port
• 8k ingress rules
• 1K egress rules
• Policy Capabilities
• Up to 12288 authenticated policy users per switch
• Policy Profiles: 63
• Unique Permit/Deny Rules per switch: 1976
• MAC Rules: 512
• IPv4 Rules: 512
• IPv6 Rules: 512
• L2 Rules: 440
• SummitStack-V400 400Gb (full duplex) stacking
• Stacking of up to 8 X590 / X690 / X695 / X870 systems
• 2 x QSFP28 ports (at 100Gb) for stacking
• SummitStack-V160 160Gbps (full duplex) stacking
• Stacking of up to 8 X465 / X695 systems
• 2 x QSFP28 ports (at 40Gb) for stacking
Environmental
Environmental Specifications
EN/ETSI 300 019-2-1 v2.1.2 - Class 1.2 Storage
EN/ETSI 300 019-2-2 v2.1.2 - Class 2.3 Transportation
EN/ETSI 300 019-2-3 v2.1.2 - Class 3.1e Operational
EN/ETSI 300 753 (1997-10) - Acoustic Noise
ASTM D3580 Random Vibration Unpackaged 1.5 G
Environmental Compliance
EU RoHS 2011/65/EU
EU WEEE 2012/19/EU
China RoHS SJ/T 11363-2006
Taiwan RoHS CNS 15663(2013.7)
Packaging and Storage Specifications
• Temp: -40° C to 70° C (-40° F to 158° F)
• Humidity: 10% to 95% relative humidity, non-condensing
• Packaged Shock (half sine): 180 m/s2 (18 G), 6 ms, 600 shocks
• Packaged Vibration: 5 to 62 Hz at velocity 5 mm/s, 62 to 500 Hz at 0.2 G
• Packaged Random Vibration: 5 to 20 Hz at 1.0 ASD w/–3 dB/oct. from 20
to 200 Hz
• Packaged Drop Height: 14 drops minimum on sides and corners at 42
inches (<15 kg box)
Regulatory and Safety
North American ITE
• UL 60950-1
• UL 62368-1
• Complies with FCC 21CFR 1040.10 (U.S. Laser Safety)
• CDRH Letter of Approval (US FDA Approval)
• CAN/CSA 22.2 No. 60950-1
• CAN/CSA No. 22.2 62368-1-14
European ITE
• EN 60950-1, EN 62368-1
• EN 60825-1Class 1 (Lasers Safety)
• 2014 / 35/ EU Low Voltage Directive
International ITE
• CB Report and Certificate per IEC 60950-1 AS/NZS 60950-1 (Australia /New
Zealand)
• IEC 62368-1
• GB 4943.1-2011
• CNS 14336-1
EMI/EMC Standards
North American EMC for ITE
• FCC CFR 47 Part 15 Class A (USA)
• ICES-003 Class A (Canada)
European EMC Standards
• EN 55032 Class A
• EN 55024
• EN 61000-3-2,2014 (Harmonics)
• EN 61000-3-3 2013 (Flicker)
• EN 300 386 v1.6.1 (EMC Telecommunications)
• 2014/30/EU EMC Directive
• EN 55011 Class A
International EMC Certifications
• CISPR 32, Class A (International Emissions)
• AS/NZS CISPR32
• CISPR 24 Class A (International Immunity)
• IEC 61000-4-2 / EN 61000-4-2 Electrostatic Discharge, 8kV Contact, 15
kV Air, Criteria A
• IEC 61000-4-3 /EN 61000-4-3 Radiated Immunity 10V/m, Criteria A
• IEC 61000-4-4 / EN 61000-4-4 Transient Burst, 1 kV, Criteria A
• IEC 61000-4-5 /EN 61000-4-5 Surge, 2 kV L-L, 2 kV L-G, Level 3, Criteria A
• IEC 61000-4-6 Conducted Immunity, 0.15-80 MHz, 10V/m unmod. RMS,
Criteria A
• IEC/EN 61000-4-11 Power Dips and Interruptions, >30%, 25 periods, Criteria
C
• IEC 61000-4-8 / EN 61000-4-8
• CISPER 11 Class A
• GB/T 9254-2008
Country Specific
• VCCI Class A (Japan Emissions)
• ACMA RCM (Australia Emissions)
• CCC Mark (China)
• KCC Mark, EMC Approval (Korea)
• EAC Mark (Custom Union)
• NRCS / SABS Mark (South Africa)
• BSMI Mark (Taiwan)
Telecom Standards
• CE 2.0 Compliant