Specifications

W W W.EXTREMENETW ORKS.COM 5
Environmental Specifications
- EN/ ETSI 300 0 19-2-1 v2.1.2 - Class 1.2 Storage
- EN/ ETSI 300 0 19-2-2 v2.1.2 - Class 2.3 Transportation
- EN/ ETSI 300 0 19-2-3 v2.1.2 - Class 3.1e Operational
- EN/ ETSI 300 753 (1997-10) - Acoustic Noise ASTM
D3580 Random Vibration Unpackaged 1.5 G
Environmental Compliance
- EU RoHS ? 2011/ 65/ EU
- EU W EEE ? 20 12/ 19/ EU
- China RoHS ? SJ/ T 11363-20 0 6
- Taiwan RoHS ? CNS 15663(20 13.7)
Packaging and Storage Specifications
- Temp: -40 ° C to 70° C (-40 ° F to 158° F)
- Humidity: 10 % to 95% relative humidity,
non-condensing
- Packaged Shock (half sine): 180 m/s2 (18 G), 6 ms,
60 0 shocks
- Packaged Vibration: 5 to 62 Hz at velocity 5 mm/s, 62
to 500 Hz at 0.2 G
- Packaged Random Vibration: 5 to 20 Hz at 1.0 ASD
w/ ?3 dB/ oct. from 20 to 200 Hz
- Packaged Drop Height: 14 drops minimum on sides
and corners at 42 inches (<15 kg box)
Regulatory and Safety
North American ITE
- UL 60 950 -1 2nd edition A2:20 14, Listed Device (U.S.)
- CSA 22.2 No. 60 950 -1 2nd edition 2014(Canada)
- Complies with FCC 21CFR 10 40.10 (U.S. Laser Safety)
- CDRH Letter of Approval (US FDA Approval)
European ITE EN
- 60 950 -1:20 0 6+A11:20 09+A1:20 10+A12:2011+A2:2013
2nd Ed.
- EN 60 825-1:2007 / IEC 60 825-1:2007 Class 1 (Lasers
Safety)
- 2014 / 35/ EU Low Voltage Directive
International ITE
- CB Report & Certificate per IEC 60 950 -1 :
2005+A1:2009+A2:20 13 + National Differences
- AS/ NZS 60 950 -1 (Australia / New Zealand)
EMI/ EMC Standards
North American EMC for ITE
- FCC CFR 47 part 15 Class A (USA)
- ICES-0 0 3 Class A (Canada)
European EMC Standards
- EN 55032:20 15 Class A
- EN 55024:20 10
- EN 610 00 -3-2,20 14 (Harmonics)
- EN 610 00 -3-3 2013 (Flicker)
- EN 300 386 v1.6.1 (EMC Telecommunications)
- 2014/ 30/ EU EMC Directive
International EMC Certifications
- CISPR 32:2015, Class A (International Emissions)
- AS/ NZS CISPR32:2015
- CISPR 24:2010 Class A (International Immunity)
- IEC 61000 -4-2:2008/ EN 610 0 0-4-2:20 0 9 Electrostatic
Discharge, 8kV Contact, 15 kV Air, Criteria A
- IEC 61000 -4-3:2010/ EN 6100 0 -4-3:2006 +A1:200 8
+A2:2010 Radiated Immunity 10 V/ m, Criteria A
- IEC 61000 -4-4:2012. / EN 61000 -4-4:2012 Transient
Burst, 1 kV, Criteria A
- IEC 61000 -4-5:20 14 / EN 610 0 0-4-5:2014 Surge, 2 kV
L-L, 2 kV L-G, Level 3, Criteria A
- IEC 61000 -4-6:20 13/ EN 610 0 0 -4-6:20 14 Conducted
Immunity, 0.15-80 MHz, 10 V/ m unmod. RMS, Criteria A
- IEC/ EN 610 00 -4-11:20 0 4 Power Dips & Interruptions,
>30%, 25 periods, Criteria C
Country Specific
- VCCI Class A (Japan Emissions)
- ACMA RCM (Australia Emissions)
- CCC Mark
- KCC Mark, EMC Approval (Korea)
Telecom Standards
- CE 2.0 Compliant