Installation Guide

Table Of Contents
Power: Summit X460-48p
Table 316: Summit X460-48p with No Option Card or Stacking Module (AC Power
Supply)
Nominal input ratings
100 to 240 V , 50/60 Hz, 5.5 A (per power supply)
Input current
5.0 A @ 100 V (low-line)
2.1 A @ 240 V (high-line)
Minimum power consumption 493 W
966 W (power supply * 2 units)
Minimum heat dissipation 1,682 BTU/hr (per power supply)
3,364 BTU/hr (power supply * 2 units)
Maximum power consumption 505 W
1010 W (power supply * 2 units)
Maximum heat dissipation 1,722 BTU/hr
3,444 BTU/hr
Table 317: CPU, Memory
CPU/Memory
600 MHz CPU
512 MB memory
2.5 MB buer, per chip
Table 318: Safety Standards
North American Safety of ITE UL 60950-1 2nd Ed., Listed Device (US)
CSA 22.2 #60950-1-03 2nd Ed.(Canada)
Complies with FCC 21CFR 1040.10 (US Laser Safety)
CDRH Letter of Approval (US FDA Approval)
European Safety of ITE EN 60950-1:2007 2nd Ed.
EN 60825-1+A2:2001 (Lasers Safety)
TUV-R GS Mark by German Notified Body
2006/95/EC Low Voltage Directive
International Safety of ITE CB Report & Certificate per IEC 60950-1 2nd Ed. + National
Dierences
AS/NZX 60950-1 (Australia /New Zealand)
Table 319: EMI/EMC Standards
North America EMC for ITE FCC CFR 47 part 15 Class A (USA)
ICES-003 Class A (Canada)
European EMC standards EN 55022:2006+A1:2007 Class A
EN 55024:A2-2003 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 11
EN 61000-3-2,8-2006 (Harmonics)
EN 61000-3-3 2008 (Flicker)
ETSI EN 300 386 v1.4.1, 2008-04 (EMC Telecommunications)
Power: Summit X460-48p Technical Specifications