Installation Guide

Table Of Contents
Figure 331: RPS Cable and AC Power Cord Connections for the RPS-150XT
1 = Switch
4 = Redundant Power Supply connector
2 = RPS cable 5 = AC power cord
3 = RPS-150XT 6 = AC power outlet with ground connection
Note
AC power cords and outlets vary depending on country.
3. Connect the AC power cord to the AC input power connector on the power supply.
4. Plug the AC power cord into the main AC power outlet.
The AC OK and DC OK LEDs on the front of the power supply turn green to indicate that the connection
was successful and the power supply is operating properly.
If the LEDs do not light properly, follow these steps to troubleshoot:
Check the AC power cord connection at the AC power source and make sure the power source is
within
specification.
Check the AC power connection to the power supply.
Swap the AC power cord with one that is known to work properly.
Installing External Power Supplies
Connecting the RPS Cable and AC Power Cord to an
RPS-150XT
Summit Family Hardware Installation Guide 395