A redundant power cable shipped with the EPS-C chassis provides the connection between the external
power system and the redundant power input connector on the back of the switch.
Note
An AC power cord is not provided with the EPS-600LS power module. See Power Cord
Requirements for AC-Powered Switches and AC Power Supplies on page 653 for information
about selecting a power cord.
Note
Each EPS-C chassis is shipped with a special redundant power supply cord for connection to
the Summit switch. Make sure that the EPS-C chassis is installed in the rack system before
installing an EPS-600LS unit.
Installing the EPS-C Chassis
Caution
Do not use the rack-mount brackets to suspend the EPS-C from under a table or desk, or to
attach the EPS-C unit to a wall.
The EPS-C is intended for use only with a Summit X450e-48p or X250e-48p switch. You can install the
EPS-C above or below the switch.
Figure 306: EPS-C and Summit Switch
To rack-mount the EPS-C in a 19-inch rack, follow these steps:
1. Place the EPS-C upright on a secure work surface.
2. Remove the mounting bracket kit from the packaging.
3. Attach the mounting brackets as follows:
a. Place a rack-mount bracket over the mounting holes on one side of the unit.
Installing the EPS-C Chassis
Installing External Power Supplies
376 Summit Family Hardware Installation Guide