Installation Guide

Table Of Contents
Connection lugs for power and ground and a screw for connecting the ground wire are shipped with the
power supply.
Preparing the Cables for a 300 W DC Power Supply
You need a crimping tool to attach the terminals to the power and ground cables.
To prepare the cable wires, follow these steps:
1. On each cable wire, strip 6 mm (0.25 inch) of insulation from one end.
2. Insert the end of one power cable wire all the way into the barrel of a spade terminal and crimp the
terminal securely to the wire.
Figure 262: Attaching a Spade Terminal to a Cable
3. Repeat step Preparing the Cables for a 300 W DC Power Supply on page 334 for the other power
cable wire.
4. Insert the end of the stripped ground wire (green or green and yellow) all the way into the barrel of
the ring terminal and crimp the terminal securely to the wire.
Figure 263: Attaching a Ring Terminal to a Ground Cable
Installing a 300 W DC Power Supply
Before installing a Summit 300 W power supply (part no. 10933 or 10944):
Verify that the switch chassis has been grounded.
Verify that the
airflow direction for the power supply is the same as the airflow direction of the
installed fan modules in the switch.
Install a 300 W Internal DC Power Supply
Installing Switches
334 Summit Family Hardware Installation Guide