4. Slide the cover o the connector.
Note
Store the connector covers for later re-use if the switch will be operated without
connecting these ports.
Caution
To ensure satisfactory protection from EMI, leave the covers on all ports that are not
connected to another VIM1-SummitStack512 module.
Connect the Cable
To connect a SummitStack 128G cable, follow these steps:
1. Holding the cable connector with the release tab on top, align the connector with the stacking port
on the VIM1 module in the Summit X650 series switch (see Figure 232).
Figure 232: Connecting a SummitStack 128G Cable
2. Firmly press the cable connector into the stacking port until the spring latch on top of the connector
clicks into place.
3. Repeat the process to connect the other end of the cable.
Connecting a SummitStack 128G/20G Stacking Cable
SummitStack 128G/20G cables are used to connect the 128-Gbps stacking ports on Summit X650 series
switches to 20-Gbps stacking ports on Summit X650 series or other Summit series switches.
Building Stacks
Connecting Stacking Cables