Installation Guide

Table Of Contents
One rear slot for fan module with front-to-back airflow.
Two dedicated QSFP-form factor 21 Gb stacking ports on the rear panel.
CONSOLE
Summit
X450-G2-24t-10GE4
10GbES FP+
25
27
28
26
MGT FAN P1 P2 S
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16
18
17 19
20
21
22
23
24
CLK ACT LINK
S2
STACK NO.
Management
5
3
4
1
2
Figure 92: X450-G2-24t-10GE4 Front Panel
1 = Stack number indicator 4 = 10/100/1000BASE-T ports
2 = Console port/Ethernet management port 5 = SFP+ 10GBASE-X ports
3 = USB port
Redundant P ower Input
! See M anual
1
2
SummitStack-V84
4 531 2
Figure 93: X450-G2-24t-10GE4 Rear Panel
1 = 21 Gb stacking ports (QSFP+)
4 = AC power input connector
2 = Redundant power supply (RPS) connector 5 = Grounding screw
3 = Front-to-back fan module slot
ExtremeSwitching X450-G2-24p-GE4 Switch Ports and Slots
X450-G2-24p-GE4 switch ports and slots include:
24 front panel PoE+ ports of 10/100/1000BASE-T (ports 1–24).
Four front panel ports of 1GBASE-X SFP (ports 25–28).
One front panel USB port.
Ethernet management port 1 x 10/100/1000BASE-T.
Serial console port implemented as an RJ45 connector used to connect a terminal and perform local
management.
One rear slot for fan module with front-to-back
airflow.
Two dedicated QSFP-form factor 21 Gb stacking ports on the rear panel.
Rear dual power supply slots with front-to-back
airflow.
Note
Unused power supply slots must be covered with blank panels.
Summit Switches
ExtremeSwitching X450-G2-24p-GE4 Switch Ports and
Slots
Summit Family Hardware Installation Guide 105