Installation Guide

Table Of Contents
5 Snap the cover into place over the terminal block.
6 Energize the DC circuit.
Replacing a 750 W Internal DC Power Supply
The ExtremeSwitching X695 switch can accommodate two 750 W DC power supply units (PSU) with
either front-to-back or back-to-front airflow.
Note
For information on replacing those units, see Install a Replacement 750 W DC Power Supply
on page 295. Bear in mind that you cannot combine power supplies of dierent wattages in
the same switch.
You need the following tools and materials to replace an 750 W DC power supply:
#1 Phillips screwdriver
Torque screwdriver and wrench or torque driver with attachments for tightening screws and nuts
Thermal protective gloves (required for removal of a power supply)
Remove a 750 W DC Power Supply
To remove an installed 750 W DC power supply, follow these steps:
Caution
The DC power supply may be hot to the touch; use thermal protective gloves when handling
the power supply during removal.
1 De-energize the DC circuit.
2 Disconnect the DC power cables:
a Pull the cover o the terminal block.
b Loosen the screws that secure the cable terminals to the terminal block.
c Slide the wires out from under the captive washers.
Warning
Be sure to disconnect all power cables before you disconnect the chassis ground wire.
3 Disconnect the ground wire as follows:
a Loosen the screw that secures the ground wire to the terminal block.
b Slide the wire out from under the captive washer.
Replacing DC Power Supplies
ExtremeSwitching and Summit Switches: Hardware Installation Guide 294