Quick Reference Guide

X465 Series Switches Quick
Reference
Follow these steps to get your switch up and running.
For complete installation instructions see the ExtremeSwitching:
Hardware Installation Guide at www.extremenetworks.com/
documentation
Tools You’ll Need
Appropriate grounded power receptacles
located within 1.8 m (6 ft.)
A readily accessible device for disconnecting
power, such as a breaker or master switch
Network cabling within reach
At least of 7.6 cm (3.0 in.) on all sides, for
proper ventilation
Temperature between 0°C (32°F) and 50°C
(122°F) with fluctuations of less than 10°C
(18°F) per hour
If the switch appears to be damaged, contact Extreme Networks. See
“Getting Help” for more information.
Extreme Networks does not include power input cords with this product.
To purchase the correct power cord for your country, refer to
www.extremenetworks.com/product/powercords/. This page lists
details for purchasing a power cord from Extreme Networks or from
your local supplier.
1 #2 Phillips screwdriver
(magnetic screwdriver recommended)
3 ESD-protective wrist strap
2 Flat-head screwdriver
1
Prepare the Site
The installation site must meet the following requirements:
2
Unpack the Box
Remove the packing material. Break the tape seal on the
non-conductive bag and remove the switch.
1 Four-post rack mount kit 2 Switch
There are several options for mounting the switch in a rack: Two options
are described here. For details about all of the options, see the Hardware
Installation Guide.
Four-Post Mount, Front Mount
This procedure uses the four-post mounting kit (XN-4P-RKMT-001),
which is included with your switch.
1 Attach a front bracket to one side of the switch, screwing it into the
holes so that the flange (ear) is flush with the front of the switch.
2 Attach the other front bracket to the other side.
3 Attach the extension brackets to both sides of the switch, using the
screws provided.
4 Attach the front brackets to the front rack posts, using the screws
provided.
5 Slide the rear brackets into the extension brackets on both sides, and
adjust them to the rack depth as shown.
6 Attach the rear brackets to the rear rack posts, using the screws
provided.
Two-Post, Mid-Mount
This procedure uses the two-post mounting kit (XN-2P-RMKIT-001),
which accommodates rack posts 3 inches or 6 inches wide and which
can be ordered separately.
1 Attach a front bracket to one side of the switch, screwing it into the
holes so that the flange (ear) is near the middle of the switch.
2 Attach the other front bracket to the other side.
3 Attach the front brackets to the front rack posts, using the screws
provided.
4 Attach the rear brackets to the rack posts, using the screws provided.
Select the right bracket length such that the rear end of the bracket is
flush with the rear of the switch,
5 Attach both rear brackets to the side of the switch, as shown.
1
To install a VIM5 module:
1 Attach the ESD wrist strap to your wrist and connect the metal end
to an appropriate ground point on the rack.
2 Ensure that the switch is completely powered down.
3 Remove the cover plate from the VIM slot (#2 Phillips screwdriver
required).
4 Remove the VIM5 module from its packaging.
5 Carefully slide the VIM5 module into the slot until it is firmly in place.
6 Secure the VIM5 module using the screws provided.
To install a transceiver:
1 Attach the ESD wrist strap to your wrist and connect the metal end
to an appropriate ground point on the rack.
2 Remove the transceiver from its packaging.
3 If applicable, remove the protective dust cover from the connector.
4 Hold the transceiver so that the connector will seat properly.
5 Carefully align the transceiver with the port slot.
6 Push the transceiver into the port slot until it clicks into place.
3
Install the Switch
You can install any X465 Series switch in a standard 19-inch
equipment rack.
Note: It is recommended to install the long rack ear in position -4 or
-5. Do not install the long rack ear in position -2 or -3, as it will block
the air openings.
4
Install VIMs, Transceivers, and SSDs
(Optional) Versatile Interface Modules (VIMs) provide
dedicated high-speed ports. Your X465 Series switch
accommodates one VIM5 module, using a slot on the front
of the switch.
Transceivers send and receive data over optical fiber rather
than through electrical wires. Insert transceivers into any of
the switchs data ports.
(Optional) Solid-state drives (SSDs) provide modular
storage support. Your X465 Series switch accommodates
one SSD module using a reserved slot on the rear of the
switch, and is supported on EXOS release 30.3 and later.
See ExtremeSwitching: Hardware Installation Guide for
details on compatible switches and SSD modules.
VIMs, transceivers, and SSDs are ordered separately.
Warning: To prevent damage to the switch or VIM, the switch
must be powered OFF when removing or installing VIMs or SSD
modules.
Note: Transceivers are Class 1 or Class 1M laser devices.
To install an SSD module:
1 Attach the ESD wrist strap to your wrist and connect the metal end
to an appropriate ground point on the rack.
2 Ensure that the switch is completely powered down.
3 Remove the cover plate from the SSD slot (#2 Phillips screwdriver
required).
4 Remove the SSD module from its packaging.
5 Carefully slide the SSD module into the slot on the rear panel until it is
firmly in place.
6 Secure the SSD module using the screws provided.
Connecting to the Primary Power Source
To attach your X465 Series switch to a power source, do the following:
1 Connect the AC power cord to the AC power input socket on the
power supply and an AC power outlet.
2 When power is connected, verify that the switch’s PWR LED turns
green. If the PWR LED does not turn green, refer to the Hardware
Installation Guide for troubleshooting information.
Operating Conditions
Operating Temperature:
0°C (32°F) to 50°C (122°F)
Temperature restrictions apply for some models at high altitudes.
See Hardware Installation Guide for details.
Storage Temperature:
-40°C to 70°C (-40°F to 158°F)
Operating Relative Humidity:
5% to 95% (non-condensing)
Safety Notices
5
Connect Power
X465 Series switches run on AC power.
Connect the switch to a primary power source.
Note: Installing the system as described in this guide meets the
protective earth grounding requirements of the National
Electrical Code (NEC), UL/CSA/IEC/EN 60950-1 standards.
However, in some cases, it may be necessary to use an
alternative grounding method. In these cases, a 14 AWG wire can
be connected between the grounding lug on the chassis and a
nearby building ground point.
6
Update and Configure
the Switch
To connect to the network, upgrade the operating-system
software to the appropriate version, and configure the
switch for use, follow the steps in
www.extrconfig.com/exos.
Electrical Hazard: Only qualified personnel should perform installation
procedures.
Risques d’électrocution: Seul un personnel qualifié doit effectuer les
procédures d'installation.
Warning: Extreme Networks power supplies do not have switches for turning
the unit on and off. Before servicing, disconnect all power cords to remove
power from the device. Make sure that these connections are easily accessible.
Avertissement: Extreme Networks alimentations ne sont pas des interrupteurs
pour allumer l'appareil et en dehors. Avant l'entretien, débranchez tous les
cordons d'alimentation pour couper l'alimentation de l'appareil. Assurez-vous
que ces connexions sont facilement accessibles.
Warning: A dedicated Listed circuit breaker rated at 15A is to be used for each
power supply connection.
Avertissement: Un disjoncteur cotée dédiée évalué à 15A doit être utilisée pour
chaque connexion d'alimentation.
Warning: Before mounting the device, ensure that the rack can support it
without compromising stability. Otherwise, personal injury and/or equipment
damage may result.
Warning: Follow appropriate ESD procedures when unpacking and handling
the switch. These include unpacking the switch in an ESD-safe environment
and wearing appropriate ESD protective gear, such as ESD-safe footwear and
ESD wrist straps where appropriate.
Warning: This unit must be installed indoors. The unit, AC power adapter, and
its cables are not designed for outdoor use.
Warning: Use of controls or adjustments or performance of procedures other
than those specified herein may result in hazardous radiation exposure.
Warning: Do not use optical instruments to view the laser output. The use of
optical instruments to view laser output increases eye hazard. Use only
UL/CSA, IEC/EN60825-1/-2 recognized pluggable modules.
Avertissement: Ne pas utiliser d'instruments optiques pour voir la sortie du
laser. L'utilisation de instruments optiques pour afficher la sortie laser
augmente les risques oculaires. Utilisez uniquement UL/CSA,
IEC/EN60825-1 /-2 reconnu modules enfichables.
Hardware Components
Figure 1 X465 Series Switch: Front Panel (48-port model shown)
Figure 2 X465 Series Switch: Rear Panel
For component details, see the Hardware Installation Guide.
Interfaces
Each X465 Series switch includes a USB micro B console port,
an RJ-45 management port, an RJ-45 console port, 2 stacking ports,
2 USB A ports for connecting to memory, and 1 unpopulated VIM5 slot.
Each switch also includes an EXOS Advanced Edge license.
Additional interfaces include:
Power Supply and Fan Options
Note: XN-ACPWR-xxx-FB power supply units cannot be used with 10941,
10951, 10953, or XN-ACPWR-2000W-F power supplies on the same switch.
Available VIM5 Modules
Available SSD Module
Available Rack-Mount Kits
1 Mode Button and System LEDs 4 Stacking ports
2 USB micro B console port 5 Access Ports
3 USB A ports
6
VIM slot, shown with VIM installed
1
Grounding lug 4 Fan modules
2
RJ-45 console and management ports
5
Power supplies
3
SSD slot (reserved)
X465-48T 48 10/100/1000Mb full/half duplex MACsec capable
ports, 3 fan modules, 2 unpopulated PSU slots
X465-48P 48 10/100/1000Mb full/half duplex MACsec capable
ports with 802.3at Type 2 PoE (30 W), 3 fan modules,
2 unpopulated PSU slots
X465-48W 48 10/100/1000Mb full/half duplex MACsec capable
ports with 802.3bt Type 4 PoE (90 W), 3 fan modules,
2 unpopulated PSU slots
X465-24MU 24 100Mb/1/2.5/5Gb ports with 802.3bt Type 3 PoE
(60 W), 2 fan modules, 2 unpopulated PSU slots
X465-24MU-24W 24 100Mb/1/2.5/5Gb ports with 802.3bt Type 3 PoE
(60 W) and 24 10/100/1000Mb full/half duplex MACsec
capable ports with 802.3bt Type 4 PoE (90 W), 3 fan
modules, 2 unpopulated PSU slots
X465-24W 24 10/100/1000Mb full/half duplex MACsec capable
ports with 802.3bt Type 4 PoE (90W), 2 fan modules,
2 unpopulated PSU slots
X465-24S 24 100Mb/1Gbps SFP ports, 3 fan modules,
2 unpopulated PSU slots
X465-24XE 24 1/10GbE SFP+ MACsec and LRM capable ports, 3
fan modules, 2 unpopulated PSU slots
X465i-48W 48 10/100/1000Mb full/half duplex MACsec capable
ports with 802.3bt Type 4 PoE (90 W), 3 fan modules,
2 unpopulated PSU slots
350W AC power supply
(10953 & XN-ACPWR-
350W-FB)
Compatible with X465-48T, X465-24S, and X465-
24XE
Front-to-back airflow
715W AC PoE power supply
(10951 & XN-ACPWR-715W-
FB)
Compatible with X465-48P, X465-48W, X465-
24MU, X465-24MU-24W, X465-24W, X465i-48W
Front-to-back airflow
1100W AC PoE power
supply
(10941 & XN-ACPWR-
1100W-FB)
Compatible with X465-48P, X465-48W, X465-
24MU, X465-24MU-24W, X465-24W, X465i-48W
Front-to-back airflow
2000W AC PoE power
supply
(XN-ACPWR-2000W-F &
XN-ACPWR-2000W-FB)
Compatible with X465-48P, X465-48W, X465-
24MU, X465-24MU-24W, X465-24W, X465i-48W
Front-to-back airflow
Spare fan module
(XN-FAN-002-F)
Spare fan module, front-to-back airflow
VIM5-4X Versatile Interface Module with 4 10GbE (SFP+) ports
VIM5-4XE Versatile Interface Module with 4 10GbE (SFP+) ports
supporting MACsec and LRM
VIM5-4YE Versatile Interface Module with 4 25GbE (SFP28) ports
supporting MACsec
VIM5-2Q Versatile Interface Module with 2 40GbE (QSFP) ports
XN-SSD-001-120 Modular 120GB SSD
XN-4P-RKMT-001 Four-post fixed rack mount kit (included)
XN-2P-RMKIT-001 Two-post fixed rack mount kit (separately orderable)

Summary of content (2 pages)