A power cord is not supplied with the controller. Use only a correctly rated power cord
certified (as appropriate) for the country of operation
.
Power Protection
● If possible, use a circuit dedicated to data processing equipment. Commercial
electrical contractors are familiar with wiring for data processing equipment and can
help with the load balancing of these circuits.
● Install surge protection. Be sure to use a surge protection device between the
electricity source and the Summit WM3600 wireless LAN controller.
● Install an Uninterruptible Power Supply (UPS). A UPS provides continuous power
during a power outage. Some UPS devices have integral surge protection. UPS
equipment requires periodic maintenance to ensure reliability. A UPS of the proper
capacity for the data processing equipment must be purchased.
Width 440mm (17.32 in)
Height 44.45mm (1.75 in)
Depth 390.8mm (15.38 in)
Weight 6.35 Kg (14.0 lbs)
Operating Temperature 0°C - 40°C
Operating Humidity 5% - 85% RH, non-condensing
Operating Altitude 3 km (10000 ft)